Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Efficacy of electrical stimulation on epidural anesthesia for cesarean section: a randomized controlled trial

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Young Sung-
dc.contributor.authorKim, Hyo Sung-
dc.contributor.authorJeong, Hyerim-
dc.contributor.authorLee, Chung Hun-
dc.contributor.authorLee, Mi Kyoung-
dc.contributor.authorChoi, Sang Sik-
dc.date.accessioned2021-08-30T21:24:21Z-
dc.date.available2021-08-30T21:24:21Z-
dc.date.created2021-06-18-
dc.date.issued2020-06-10-
dc.identifier.issn1471-2253-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/55037-
dc.description.abstractBackground Loss of resistance (LOR) technique is a widely used method to identify the epidural space. However, cases of inadequate epidural anesthesia in cesarean section were frequently reported. Also, the success rate of epidural anesthesia with LOR technique varied depending on the proficiency of the practitioner. The purpose of this study was to assess the efficacy and safety of electrical stimulation to identify epidural spaces in cesarean section for novices or clinicians with recent gap in experience. Methods Pregnant women scheduled for elective cesarean section were randomly allocated to two groups. Groups were classified based on the methods used for identifying the epidural space: the LOR group (group L) and the LOR with epidural electrical stimulation group (group E). Clinicians with less than 10 epidural cesarean section experiences in the recent year performed epidural anesthesia for cesarean section. In the group E, a RegionalStim (R) conductive catheter was inserted through the Tuohy needle, and the guidewire passing through the catheter was connected to a peripheral nerve stimulator. The intensity of the stimulation was gradually increased from 0.25 mA to 1.5 mA until paresthesia was elicited and radiated. We assessed the success of epidural anesthesia (complete success, partial success or failure). Other clinical parameters including maternal satisfaction, time required for epidural anesthesia, neonatal Apgar scores, pain scores and adverse events were compared between the two groups. Results Except for 6 patients who withdrew consent, 54 patients were enrolled in this study (28 for the group L and 26 for the group E). The demographic data showed no difference between the two groups. There was no adverse event resulted from electrical stimulation. The group E showed higher rate of complete success, sensitivity in finding epidural space and maternal satisfaction compared to the group L (21/26 vs. 15/28,p = 0.034, 0.96 vs. 0.68,p = 0.012 and 4.04 vs. 3.39,p = 0.02, respectively). The other clinical parameters showed no differences between the two groups. Conclusion In addition to the conventional LOR technique, identifying epidural spaces using electrical stimulation led to better outcomes without additional risks for novices as well as clinicians with recent gap in experience.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherBMC-
dc.subjectNERVE-STIMULATION-
dc.subjectRISK-FACTORS-
dc.subjectCATHETER-
dc.subjectANALGESIA-
dc.subjectCONFIRMATION-
dc.subjectFAILURE-
dc.titleEfficacy of electrical stimulation on epidural anesthesia for cesarean section: a randomized controlled trial-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Young Sung-
dc.contributor.affiliatedAuthorLee, Mi Kyoung-
dc.contributor.affiliatedAuthorChoi, Sang Sik-
dc.identifier.doi10.1186/s12871-020-01063-1-
dc.identifier.scopusid2-s2.0-85086354504-
dc.identifier.wosid000542202500001-
dc.identifier.bibliographicCitationBMC ANESTHESIOLOGY, v.20, no.1-
dc.relation.isPartOfBMC ANESTHESIOLOGY-
dc.citation.titleBMC ANESTHESIOLOGY-
dc.citation.volume20-
dc.citation.number1-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaAnesthesiology-
dc.relation.journalWebOfScienceCategoryAnesthesiology-
dc.subject.keywordPlusNERVE-STIMULATION-
dc.subject.keywordPlusRISK-FACTORS-
dc.subject.keywordPlusCATHETER-
dc.subject.keywordPlusANALGESIA-
dc.subject.keywordPlusCONFIRMATION-
dc.subject.keywordPlusFAILURE-
dc.subject.keywordAuthorCesarean section-
dc.subject.keywordAuthorElectrical stimulation-
dc.subject.keywordAuthorEpidural anesthesia-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Sang Sik photo

Choi, Sang Sik
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE