ETView VivaSight single lumen vs. conventional intubation in simulated studies: a systematic review and meta-analysis
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oh, Seok Kyeong | - |
dc.contributor.author | Lim, Byung Gun | - |
dc.contributor.author | Kim, Young Sung | - |
dc.contributor.author | Lee, Jae Hak | - |
dc.contributor.author | Won, Young Ju | - |
dc.date.accessioned | 2021-08-30T22:20:50Z | - |
dc.date.available | 2021-08-30T22:20:50Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2020-06 | - |
dc.identifier.issn | 0300-0605 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/55509 | - |
dc.description.abstract | Objective The ETView VivaSight single lumen airway tube (ETView) is a tracheal tube incorporating a video camera. We carried out a meta-analysis of previous simulation studies by inexperienced personnel to determine if the ETView could improve the success rate of first-attempt intubation. Methods We collected data from randomized controlled trials comparing the use of the ETView VivaSight single lumen versus a conventional endotracheal tube in a simulated manikin or cadaver study. Results Eleven studies (558 participants, 3,254 intubations, and 19 scenarios) were included. The ETView had a significantly higher success rate and shorter insertion time than conventional intubation in both normal airways (with or without chest compression) and in difficult airways. In addition, the ETView demonstrated better results in terms of a higher rate of Cormack-Lehane grade 1 and a lower incidence of dental trauma. Conclusions Inexperienced personnel can insert the ETView more rapidly and with a higher intubation success rate compared with a conventional tube. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SAGE PUBLICATIONS LTD | - |
dc.subject | IMMOBILIZED CERVICAL-SPINE | - |
dc.subject | TRACHEAL INTUBATION | - |
dc.subject | DIRECT LARYNGOSCOPY | - |
dc.subject | ENDOTRACHEAL INTUBATION | - |
dc.subject | MACINTOSH LARYNGOSCOPES | - |
dc.subject | AIRWAY MANAGEMENT | - |
dc.subject | CLASSIC LMA | - |
dc.subject | PARAMEDICS | - |
dc.subject | MANNEQUIN | - |
dc.subject | TUBE | - |
dc.title | ETView VivaSight single lumen vs. conventional intubation in simulated studies: a systematic review and meta-analysis | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Oh, Seok Kyeong | - |
dc.contributor.affiliatedAuthor | Lim, Byung Gun | - |
dc.contributor.affiliatedAuthor | Won, Young Ju | - |
dc.identifier.doi | 10.1177/0300060520925653 | - |
dc.identifier.scopusid | 2-s2.0-85086848259 | - |
dc.identifier.wosid | 000545625000001 | - |
dc.identifier.bibliographicCitation | JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, v.48, no.6 | - |
dc.relation.isPartOf | JOURNAL OF INTERNATIONAL MEDICAL RESEARCH | - |
dc.citation.title | JOURNAL OF INTERNATIONAL MEDICAL RESEARCH | - |
dc.citation.volume | 48 | - |
dc.citation.number | 6 | - |
dc.type.rims | ART | - |
dc.type.docType | Review | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Research & Experimental Medicine | - |
dc.relation.journalResearchArea | Pharmacology & Pharmacy | - |
dc.relation.journalWebOfScienceCategory | Medicine, Research & Experimental | - |
dc.relation.journalWebOfScienceCategory | Pharmacology & Pharmacy | - |
dc.subject.keywordPlus | IMMOBILIZED CERVICAL-SPINE | - |
dc.subject.keywordPlus | TRACHEAL INTUBATION | - |
dc.subject.keywordPlus | DIRECT LARYNGOSCOPY | - |
dc.subject.keywordPlus | ENDOTRACHEAL INTUBATION | - |
dc.subject.keywordPlus | MACINTOSH LARYNGOSCOPES | - |
dc.subject.keywordPlus | AIRWAY MANAGEMENT | - |
dc.subject.keywordPlus | CLASSIC LMA | - |
dc.subject.keywordPlus | PARAMEDICS | - |
dc.subject.keywordPlus | MANNEQUIN | - |
dc.subject.keywordPlus | TUBE | - |
dc.subject.keywordAuthor | Airway management | - |
dc.subject.keywordAuthor | laryngoscope | - |
dc.subject.keywordAuthor | tracheal intubation | - |
dc.subject.keywordAuthor | manikin | - |
dc.subject.keywordAuthor | simulation | - |
dc.subject.keywordAuthor | meta-analysis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.