Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Safety of Ligasure exact dissector in thyroidectomy with continuous neuromonitoring: a porcine model

Full metadata record
DC Field Value Language
dc.contributor.authorHuang, Tzu-Yen-
dc.contributor.authorLin, Yi-Chu-
dc.contributor.authorTseng, Hsin-Yi-
dc.contributor.authorDionigi, Gianlorenzo-
dc.contributor.authorKim, Hoon-Yub-
dc.contributor.authorLu, I-Cheng-
dc.contributor.authorChang, Pi-Ying-
dc.contributor.authorChiang, Feng-Yu-
dc.contributor.authorWu, Che-Wei-
dc.date.accessioned2021-08-30T22:23:18Z-
dc.date.available2021-08-30T22:23:18Z-
dc.date.created2021-06-18-
dc.date.issued2020-06-
dc.identifier.issn2227-684X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/55527-
dc.description.abstractBackground: The purpose of this study was to investigate and define safety parameters for using the Ligasure exact dissector (LED) for dissection close to the recurrent laryngeal nerve (RLN) during thyroidectomy. Methods: Real-time electrophysiologic electromyographic (EMG) tracings were recorded in 16 RLNs (8 piglets) during various applications of LED under continuous intraoperative monitoring in this prospective porcine model study. In the activation study, LED was activated at varying distances from the RLN. In the cooling study, LED was activated with different cooling times or after touching the sternodeidomastoid muscle before application to the RLN. Results: In the activation study, no adverse EMG events occurred at distances longer than I rum. In the cooling study, no adverse EMG events occurred after a 2-second cooling time. Additionally, no adverse EMG events occurred when a sternodeidomastoid muscle touch maneuver was used for cooling. Conclusions: The LED can be safely used at distance of 1 mm or longer, and it should be cooled for at least 2 seconds or by muscle touch maneuver. Thyroid surgeons can avoid RLN injury if standard procedures for LED use are observed.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherAME PUBL CO-
dc.subjectRECURRENT LARYNGEAL NERVE-
dc.subjectHARMONIC SCALPEL-
dc.subjectSURGERY-
dc.subjectINJURY-
dc.titleSafety of Ligasure exact dissector in thyroidectomy with continuous neuromonitoring: a porcine model-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Hoon-Yub-
dc.identifier.doi10.21037/gs.2020.03.17-
dc.identifier.scopusid2-s2.0-85087301172-
dc.identifier.wosid000544808800013-
dc.identifier.bibliographicCitationGLAND SURGERY, v.9, no.3, pp.702 - 710-
dc.relation.isPartOfGLAND SURGERY-
dc.citation.titleGLAND SURGERY-
dc.citation.volume9-
dc.citation.number3-
dc.citation.startPage702-
dc.citation.endPage710-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusRECURRENT LARYNGEAL NERVE-
dc.subject.keywordPlusHARMONIC SCALPEL-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordPlusINJURY-
dc.subject.keywordAuthorRecurrent laryngeal nerve (RLN)-
dc.subject.keywordAuthorLigasure exact dissector (LED)-
dc.subject.keywordAuthorcontinuous neuromonitoring-
dc.subject.keywordAuthorthyroid surgery-
dc.subject.keywordAuthornerve thermal injury-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hoon Yub photo

Kim, Hoon Yub
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE