Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Gamma3 nail with U-Blade (RC) lag screw is effective with better surgical outcomes in trochanteric hip fractures

Full metadata record
DC Field Value Language
dc.contributor.authorHan, Seung-Beom-
dc.contributor.authorJung, Jae-Kyun-
dc.contributor.authorJang, Chul-Young-
dc.contributor.authorKwak, Dae-Kyung-
dc.contributor.authorKim, Jeong-Woo-
dc.contributor.authorYoo, Je-Hyun-
dc.date.accessioned2021-08-31T04:10:06Z-
dc.date.available2021-08-31T04:10:06Z-
dc.date.created2021-06-18-
dc.date.issued2020-04-07-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/56645-
dc.description.abstractThe objective of this retrospective study was to investigate the surgical outcomes of AO/OTA 31 A1-3 trochanteric fractures treated with the new-generation Gamma3 nail with U-Blade (RC) lag screw and to analyze the risk factors related to fixation failure. A total of 318 consecutive patients who underwent cephalomedullary nailing using Gamma3 nail with U-Blade lag screw for trochanteric hip fractures between September 2015 and June 2018 were enrolled. The average age was 80 years and most patients (69%) were women. The mean follow-up was 12.2 months with a minimum of 6 months. 309 (97.2%) showed bony union with a mean time to union of 13.5 +/- 8.7 weeks. Cut-out occurred in 2 patients (0.6%) and 7 patients showed excessive collapse (>= 15 mm) of the proximal fragment. These 9 patients were assigned to the failure group. The presence of a basicervical fracture component and comminution of the anterior cortex on preoperative 3-D CT showed a significant association with fixation failure, including cut-out, although comminution of the anterior cortex was the only independent risk factor for fixation failure on multivariate logistic regression analysis. Gamma3 nail with U-Blade lag screw showed favorable results for trochanteric hip fractures, with low cut-out rate (0.6%). However, more caution is required in treating trochanteric fractures with a basicervical fracture component and anterior cortex comminution even with this nail.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherNATURE PUBLISHING GROUP-
dc.subjectPERTROCHANTERIC FEMORAL FRACTURES-
dc.subjectINTERTROCHANTERIC FRACTURES-
dc.subjectPROXIMAL FEMUR-
dc.subjectFIXATION-
dc.subject3RD-GENERATION-
dc.subjectANTIROTATION-
dc.subjectFAILURE-
dc.subjectDEVICE-
dc.titleGamma3 nail with U-Blade (RC) lag screw is effective with better surgical outcomes in trochanteric hip fractures-
dc.typeArticle-
dc.contributor.affiliatedAuthorHan, Seung-Beom-
dc.identifier.doi10.1038/s41598-020-62980-2-
dc.identifier.scopusid2-s2.0-85083067021-
dc.identifier.wosid000549142200021-
dc.identifier.bibliographicCitationSCIENTIFIC REPORTS, v.10, no.1-
dc.relation.isPartOfSCIENTIFIC REPORTS-
dc.citation.titleSCIENTIFIC REPORTS-
dc.citation.volume10-
dc.citation.number1-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusPERTROCHANTERIC FEMORAL FRACTURES-
dc.subject.keywordPlusINTERTROCHANTERIC FRACTURES-
dc.subject.keywordPlusPROXIMAL FEMUR-
dc.subject.keywordPlusFIXATION-
dc.subject.keywordPlus3RD-GENERATION-
dc.subject.keywordPlusANTIROTATION-
dc.subject.keywordPlusFAILURE-
dc.subject.keywordPlusDEVICE-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE