Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Domain-invariant interpretable fundus image quality assessment

Full metadata record
DC Field Value Language
dc.contributor.authorShen, Yaxin-
dc.contributor.authorSheng, Bin-
dc.contributor.authorFang, Ruogu-
dc.contributor.authorLi, Huating-
dc.contributor.authorDai, Ling-
dc.contributor.authorStolte, Skylar-
dc.contributor.authorQin, Jing-
dc.contributor.authorJia, Weiping-
dc.contributor.authorShen, Dinggang-
dc.date.accessioned2021-08-31T04:50:56Z-
dc.date.available2021-08-31T04:50:56Z-
dc.date.created2021-06-19-
dc.date.issued2020-04-
dc.identifier.issn1361-8415-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/56797-
dc.description.abstractObjective and quantitative assessment of fundus image quality is essential for the diagnosis of retinal diseases. The major factors in fundus image quality assessment are image artifact, clarity, and field definition. Unfortunately, most of existing quality assessment methods focus on the quality of overall image, without interpretable quality feedback for real-time adjustment. Furthermore, these models are often sensitive to the specific imaging devices, and cannot generalize well under different imaging conditions. This paper presents a new multi-task domain adaptation framework to automatically assess fundus image quality. The proposed framework provides interpretable quality assessment with both quantitative scores and quality visualization for potential real-time image recapture with proper adjustment. In particular, the present approach can detect optic disc and fovea structures as landmarks, to assist the assessment through coarse-to-fine feature encoding. The framework also exploit semi-tied adversarial discriminative domain adaptation to make the model generalizable across different data sources. Experimental results demonstrated that the proposed algorithm outperforms different state-of-the-art approaches and achieves an area under the ROC curve of 0.9455 for the overall quality classification. (C) 2020 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER-
dc.titleDomain-invariant interpretable fundus image quality assessment-
dc.typeArticle-
dc.contributor.affiliatedAuthorShen, Dinggang-
dc.identifier.doi10.1016/j.media.2020.101654-
dc.identifier.scopusid2-s2.0-85079546595-
dc.identifier.wosid000521115200014-
dc.identifier.bibliographicCitationMEDICAL IMAGE ANALYSIS, v.61-
dc.relation.isPartOfMEDICAL IMAGE ANALYSIS-
dc.citation.titleMEDICAL IMAGE ANALYSIS-
dc.citation.volume61-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryComputer Science, Artificial Intelligence-
dc.relation.journalWebOfScienceCategoryComputer Science, Interdisciplinary Applications-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordAuthorFundus image quality assessment-
dc.subject.keywordAuthorDomain adaptation-
dc.subject.keywordAuthorInterpretability-
dc.subject.keywordAuthorMulti-task learning-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Artificial Intelligence > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE