Domain-invariant interpretable fundus image quality assessment
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shen, Yaxin | - |
dc.contributor.author | Sheng, Bin | - |
dc.contributor.author | Fang, Ruogu | - |
dc.contributor.author | Li, Huating | - |
dc.contributor.author | Dai, Ling | - |
dc.contributor.author | Stolte, Skylar | - |
dc.contributor.author | Qin, Jing | - |
dc.contributor.author | Jia, Weiping | - |
dc.contributor.author | Shen, Dinggang | - |
dc.date.accessioned | 2021-08-31T04:50:56Z | - |
dc.date.available | 2021-08-31T04:50:56Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2020-04 | - |
dc.identifier.issn | 1361-8415 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/56797 | - |
dc.description.abstract | Objective and quantitative assessment of fundus image quality is essential for the diagnosis of retinal diseases. The major factors in fundus image quality assessment are image artifact, clarity, and field definition. Unfortunately, most of existing quality assessment methods focus on the quality of overall image, without interpretable quality feedback for real-time adjustment. Furthermore, these models are often sensitive to the specific imaging devices, and cannot generalize well under different imaging conditions. This paper presents a new multi-task domain adaptation framework to automatically assess fundus image quality. The proposed framework provides interpretable quality assessment with both quantitative scores and quality visualization for potential real-time image recapture with proper adjustment. In particular, the present approach can detect optic disc and fovea structures as landmarks, to assist the assessment through coarse-to-fine feature encoding. The framework also exploit semi-tied adversarial discriminative domain adaptation to make the model generalizable across different data sources. Experimental results demonstrated that the proposed algorithm outperforms different state-of-the-art approaches and achieves an area under the ROC curve of 0.9455 for the overall quality classification. (C) 2020 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER | - |
dc.title | Domain-invariant interpretable fundus image quality assessment | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Shen, Dinggang | - |
dc.identifier.doi | 10.1016/j.media.2020.101654 | - |
dc.identifier.scopusid | 2-s2.0-85079546595 | - |
dc.identifier.wosid | 000521115200014 | - |
dc.identifier.bibliographicCitation | MEDICAL IMAGE ANALYSIS, v.61 | - |
dc.relation.isPartOf | MEDICAL IMAGE ANALYSIS | - |
dc.citation.title | MEDICAL IMAGE ANALYSIS | - |
dc.citation.volume | 61 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Computer Science | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Computer Science, Artificial Intelligence | - |
dc.relation.journalWebOfScienceCategory | Computer Science, Interdisciplinary Applications | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordAuthor | Fundus image quality assessment | - |
dc.subject.keywordAuthor | Domain adaptation | - |
dc.subject.keywordAuthor | Interpretability | - |
dc.subject.keywordAuthor | Multi-task learning | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.