Case Study: Safety Assessment of Plant Layout between Ethylene Storage Tanks and Process Equipment According to Capacity and Weather Conditions

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Jae-Young-
dc.contributor.authorByeon, Sang-Hoon-
dc.date.accessioned2021-08-31T04:56:58Z-
dc.date.available2021-08-31T04:56:58Z-
dc.date.created2021-06-18-
dc.date.issued2020-04-
dc.identifier.issn1661-7827-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/56844-
dc.description.abstractIn a chemical plant, even if an explosion occurs in a storage tank that handles flammable materials, the minimum separation distance is applied in a way to prevent chain explosion. This is because when an explosion occurs in a storage tank, thermal radiation affects nearby process equipment and causes a chain explosion. The separation distance between storage tanks and process equipment in a chemical plant depends on the global engineering guidelines PIP (Process Industry Practice) PNE00003 and GAPS (Global Asset Protection Services) GAP.2.5.2. However, there is a limitation in the global engineering guidelines that provide only a consistent separation distance according to the item types without considering the storage capacity and climatic conditions around the storage tank. This study analyzed the distance of thermal radiation (up to 37.5 kW/m(2)) according to the capacity of ethylene storage tank and climatic conditions by utilizing the Phast (DNV GL), which is widely used as a tool for quantitative risk analysis. The accident scenario was applied using the U.S. EPA (Environment Protection Agency)'s worst leakage accident scenario, considering climate variables, air temperature, wind speed, and atmospheric stability. In the simulation, atmospheric stability did not affect the radius of thermal radiation. Moreover, the thermal radiation tended to increase with increase in wind speed in the ambient condition and winter, but not in summer. Because both PIP PNE00003 and GAP.2.5.2 yield consistent separation distances without considering storage capacity and weather conditions, quantitative risk analysis of the results of thermal radiation is necessary to ensure safety.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherMDPI-
dc.subjectQRA-
dc.titleCase Study: Safety Assessment of Plant Layout between Ethylene Storage Tanks and Process Equipment According to Capacity and Weather Conditions-
dc.typeArticle-
dc.contributor.affiliatedAuthorByeon, Sang-Hoon-
dc.identifier.doi10.3390/ijerph17082849-
dc.identifier.scopusid2-s2.0-85084030532-
dc.identifier.wosid000535744100234-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, v.17, no.8-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH-
dc.citation.titleINTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH-
dc.citation.volume17-
dc.citation.number8-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassssci-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalResearchAreaPublic, Environmental & Occupational Health-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryPublic, Environmental & Occupational Health-
dc.subject.keywordPlusQRA-
dc.subject.keywordAuthorsafety distance-
dc.subject.keywordAuthorQRA-
dc.subject.keywordAuthorweather variable-
dc.subject.keywordAuthorethylene-
dc.subject.keywordAuthorthermal radiation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Byeon, Sang Hoon photo

Byeon, Sang Hoon
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE