Coded aperture imager with depth of interaction scintillators
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Taewoong | - |
dc.contributor.author | Lee, Hyounggun | - |
dc.contributor.author | Lee, Wonho | - |
dc.date.accessioned | 2021-08-31T09:44:29Z | - |
dc.date.available | 2021-08-31T09:44:29Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2020-02-21 | - |
dc.identifier.issn | 0168-9002 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/57617 | - |
dc.description.abstract | In this study, a coded-aperture imager with a depth of interaction (DOI) detector was designed and its performance was evaluated using a Monte Carlo simulation. The DOI coded-aperture imager consisted of a modified uniformly redundant array (MURA) and four layers of a 16 x 16 matrix of 2 mm cubic scintillators. To improve its performance, the reconstructed images from each layer were combined using a hybrid maximum likelihood expectation maximization (h-MLEM) technique. The DOI coded-aperture imager demonstrated higher signal-to-noise ratios (SNRs) in the reconstructed images, when compared with conventional coded-aperture imagers with 2D pixelated scintillators. In addition, various types of scintillators were tested and compared with respect to their RV curves, detection efficiencies, and SNRs. Among the tested scintillators, gadolinium aluminum gallium garnet (GAGG) demonstrated the highest performance above 356 keV. However, for low-energy radiation (< 200 keV), the performance of all the scintillators were similar. Because the timing resolution is shorter than those of other scintillators, LaBr3 could show a relatively high performance for measurement in high background conditions. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER | - |
dc.subject | GAMMA | - |
dc.subject | PERFORMANCE | - |
dc.subject | DETECTOR | - |
dc.title | Coded aperture imager with depth of interaction scintillators | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Wonho | - |
dc.identifier.doi | 10.1016/j.nima.2019.01.010 | - |
dc.identifier.scopusid | 2-s2.0-85060278502 | - |
dc.identifier.wosid | 000511297400099 | - |
dc.identifier.bibliographicCitation | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.954 | - |
dc.relation.isPartOf | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | - |
dc.citation.title | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | - |
dc.citation.volume | 954 | - |
dc.type.rims | ART | - |
dc.type.docType | Article; Proceedings Paper | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Physics, Nuclear | - |
dc.relation.journalWebOfScienceCategory | Physics, Particles & Fields | - |
dc.subject.keywordPlus | GAMMA | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | DETECTOR | - |
dc.subject.keywordAuthor | DOI coded aperture imager | - |
dc.subject.keywordAuthor | Hybrid update maximum likelihood expectation maximization (h-MLEM) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.