Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Image intensification - A solution for difficult guidewire insertion for central venous access: A case report

Full metadata record
DC Field Value Language
dc.contributor.authorWeinberg, Laurence-
dc.contributor.authorBBiomed, Matthew Yii-
dc.contributor.authorLi BBiomed, Michael-
dc.contributor.authorBBiomed, Maleck Louis-
dc.contributor.authorLee, Dong Kyu-
dc.contributor.authorDoolan, Laurie-
dc.date.accessioned2021-08-31T11:25:05Z-
dc.date.available2021-08-31T11:25:05Z-
dc.date.created2021-06-18-
dc.date.issued2020-02-
dc.identifier.issn2049-0801-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/57802-
dc.description.abstractPresentation of case: A 56-year old male presented for an elective redo-sternotomy, aortic valve replacement, tricuspid valve annuloplasty, and coronary artery bypass grafting. During central vascular access using a standard Seldinger technique, resistance to two spring-wire guide wires was encountered when the wires were advanced through the patient's internal jugular vein. Ultrasound provided limited views of the anatomical path of the guidewires and was unable to provide visualisation of the level or cause of obstruction. We describe the application of continuous image intensification to successfully identify the anatomical location and safe circumnavigation of guidewire obstruction during the insertion of a central venous and pulmonary artery catheter for cardiac surgery. Discussion: The use of x-ray image intensification enabled the immediate identification of the cause of obstruction, minimising further attempts at guidewire insertion and subsequent complications. The direct real-time visualisation allowed for manoeuvres such as wire manipulation, rotation and advancement to be safely performed. Conclusion: Image intensification may decrease malposition rates and mechanical complications associated with difficult central venous catheterisation. Further research comparing the safety and efficiency of ultrasound-guided and fluoroscopy-guided CVC insertion should be contemplated.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.subjectJUGULAR-VEIN CATHETERIZATION-
dc.subjectCOMPLICATIONS-
dc.subjectULTRASOUND-
dc.subjectFLUOROSCOPY-
dc.subjectMANAGEMENT-
dc.subjectPLACEMENT-
dc.titleImage intensification - A solution for difficult guidewire insertion for central venous access: A case report-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Dong Kyu-
dc.identifier.doi10.1016/j.amsu.2019.12.005-
dc.identifier.scopusid2-s2.0-85077644354-
dc.identifier.wosid000509984900007-
dc.identifier.bibliographicCitationANNALS OF MEDICINE AND SURGERY, v.50, pp.31 - 34-
dc.relation.isPartOfANNALS OF MEDICINE AND SURGERY-
dc.citation.titleANNALS OF MEDICINE AND SURGERY-
dc.citation.volume50-
dc.citation.startPage31-
dc.citation.endPage34-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusJUGULAR-VEIN CATHETERIZATION-
dc.subject.keywordPlusCOMPLICATIONS-
dc.subject.keywordPlusULTRASOUND-
dc.subject.keywordPlusFLUOROSCOPY-
dc.subject.keywordPlusMANAGEMENT-
dc.subject.keywordPlusPLACEMENT-
dc.subject.keywordAuthorCentral venous catheter-
dc.subject.keywordAuthorImage intensification-
dc.subject.keywordAuthorUltrasound-
dc.subject.keywordAuthorGuidewire-
dc.subject.keywordAuthorCardiac surgery-
dc.subject.keywordAuthorAnaesthesia-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE