Effects of type of magnet attachment and implant angulation in two implant overdenture models

Full metadata record
DC Field Value Language
dc.contributor.authorSong, So-Yeon-
dc.contributor.authorKang, Kyeong-Hwan-
dc.contributor.authorLee, Jeong-Yol-
dc.contributor.authorShin, Sang-Wan-
dc.date.accessioned2021-08-31T11:41:05Z-
dc.date.available2021-08-31T11:41:05Z-
dc.date.created2021-06-18-
dc.date.issued2020-02-
dc.identifier.issn2005-7806-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/57907-
dc.description.abstractPURPOSE. The purpose of this study is to evaluate the effects of type of magnet attachment and implant angulation in two implant overdenture models. MATERIALS AND METHODS. Magnet attachments used in this study were flat and dome types (MGT5515, MGT5520D, Pentium Co., Seoul, Korea). Two implants with keepers were inserted in the resin blocks at a distance of 24 mm. For the first model, the implants were parallel to the vertical and perpendicular to the horizontal; for the second model, both were angulated 5 degrees to the mesial; for the third model, both were angulated 10 degrees toward the mesial. The retentive force was measured in both vertical and lateral directions. Statistical analyses were performed using SPSS software version 22.0 (alpha=.05). RESULTS. The flat type magnet attachment showed the highest lateral retentive force in the 20 degrees divergent group (P<.05) and the dome type magnet attachment showed the highest lateral retentive force in the parallel group (P<.05). The vertical and lateral retentive force of the dome type magnet attachment was greater than that of the flat type magnet attachment in every direction (P<.05). CONCLUSION. Within the limitations of this study, the dome shape magnet attachment can resist vertical and lateral retentive force more superiorly than the flat type magnet attachment, regardless of angle, in the mandibular two implant model.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN ACAD PROSTHODONTICS-
dc.subjectRETENTION-
dc.subjectSYSTEMS-
dc.subjectFORCES-
dc.titleEffects of type of magnet attachment and implant angulation in two implant overdenture models-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Jeong-Yol-
dc.identifier.doi10.4047/jap.2020.12.1.33-
dc.identifier.scopusid2-s2.0-85084736221-
dc.identifier.wosid000517195200005-
dc.identifier.bibliographicCitationJOURNAL OF ADVANCED PROSTHODONTICS, v.12, no.1, pp.33 - 37-
dc.relation.isPartOfJOURNAL OF ADVANCED PROSTHODONTICS-
dc.citation.titleJOURNAL OF ADVANCED PROSTHODONTICS-
dc.citation.volume12-
dc.citation.number1-
dc.citation.startPage33-
dc.citation.endPage37-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002558396-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaDentistry, Oral Surgery & Medicine-
dc.relation.journalWebOfScienceCategoryDentistry, Oral Surgery & Medicine-
dc.subject.keywordPlusRETENTION-
dc.subject.keywordPlusSYSTEMS-
dc.subject.keywordPlusFORCES-
dc.subject.keywordAuthorTwo implant overdenture model-
dc.subject.keywordAuthorMagnet attachments-
dc.subject.keywordAuthorImplant angulation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE