Feasibility of Attachable Ring Stimulator for Intraoperative Neuromonitoring during Thyroid Surgery
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Jongjin | - |
dc.contributor.author | Moon, Hyeon Jong | - |
dc.contributor.author | Chai, Young Jun | - |
dc.contributor.author | Lee, Jung-Man | - |
dc.contributor.author | Hwang, Ki-Tae | - |
dc.contributor.author | Wu, Che-Wei | - |
dc.contributor.author | Dionigi, Gianlorenzo | - |
dc.contributor.author | Kim, Hoon Yub | - |
dc.contributor.author | Park, Kyung Sik | - |
dc.contributor.author | Kim, Sang Wan | - |
dc.contributor.author | Yi, Ka Hee | - |
dc.date.accessioned | 2021-08-31T11:45:09Z | - |
dc.date.available | 2021-08-31T11:45:09Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2020-01-30 | - |
dc.identifier.issn | 1687-8337 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/57936 | - |
dc.description.abstract | Objective. Stimulator-attached dissecting instruments are useful for intraoperative nerve monitoring during thyroidectomy. The aim of this study was to evaluate the feasibility of an attachable ring stimulator (ARS) by comparing the electromyography (EMG) amplitudes evoked by an ARS and a conventional stimulator. Methods. Medical records of fourteen patients who underwent thyroidectomy using intraoperative neuromonitoring between June and August 2019 were retrospectively reviewed. The amplitudes of V1, R1, R2, and V2 signals were checked using both the ARS and a conventional stimulator, at the same point. Results. Both stimulators were tested on 20 recurrent laryngeal nerves (RLNs) and 20 vagus nerves (VNs). In all the nerves, the amplitudes of V1, R1, R2, and V2 were greater than 500 mu V. The mean amplitudes of V1, R1, R2, and V2 checked with the ARS were 1175, 1432, 1598, and 1279 mu V, respectively. The mean amplitudes of V1, R1, R2, and V2 checked with the conventional stimulator were 1140, 1425, 1557, and 1217 mu V, respectively. Difference between amplitudes evoked by the two stimulators for V1, R1, R2, and V2 was 77, 110, 102, and 99 mu V, respectively. There was no statistical difference in the amplitudes between the two groups for V1, R1, R2, and V2. Conclusion. The ARS transferred electric stimulation as effectively as the conventional stimulator. It is an effective tool for repeated stimulation and facilitates continuous feedback regarding the functional integrity of nerves during thyroid surgery. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | HINDAWI LTD | - |
dc.subject | RECURRENT LARYNGEAL NERVE | - |
dc.subject | ENDOTRACHEAL-TUBE | - |
dc.subject | SAFETY | - |
dc.subject | IDENTIFICATION | - |
dc.subject | PREVENTION | - |
dc.subject | INJURY | - |
dc.subject | RLN | - |
dc.title | Feasibility of Attachable Ring Stimulator for Intraoperative Neuromonitoring during Thyroid Surgery | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Hoon Yub | - |
dc.identifier.doi | 10.1155/2020/5280939 | - |
dc.identifier.scopusid | 2-s2.0-85079295086 | - |
dc.identifier.wosid | 000514325800001 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, v.2020 | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF ENDOCRINOLOGY | - |
dc.citation.title | INTERNATIONAL JOURNAL OF ENDOCRINOLOGY | - |
dc.citation.volume | 2020 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Endocrinology & Metabolism | - |
dc.relation.journalWebOfScienceCategory | Endocrinology & Metabolism | - |
dc.subject.keywordPlus | RECURRENT LARYNGEAL NERVE | - |
dc.subject.keywordPlus | ENDOTRACHEAL-TUBE | - |
dc.subject.keywordPlus | SAFETY | - |
dc.subject.keywordPlus | IDENTIFICATION | - |
dc.subject.keywordPlus | PREVENTION | - |
dc.subject.keywordPlus | INJURY | - |
dc.subject.keywordPlus | RLN | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.