Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Design optimization of bare tube heat exchanger for the application to mobile air conditioning systems

Full metadata record
DC Field Value Language
dc.contributor.authorLim, Hongyoung-
dc.contributor.authorHan, Ukmin-
dc.contributor.authorLee, Hoseong-
dc.date.accessioned2021-08-31T12:05:11Z-
dc.date.available2021-08-31T12:05:11Z-
dc.date.created2021-06-19-
dc.date.issued2020-01-25-
dc.identifier.issn1359-4311-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/57950-
dc.description.abstractA louver fin heat exchanger (LFHX) has been widely used as an evaporator in the mobile air conditioning system due to its high heat transfer performance. However, there is an inherent problem of the LFHX such that it is poorly drained due to the fins. This causes problems with odor, corrosion, and window fogging. The purpose of the study is to investigate a bare tube heat exchanger (BTHX) to overcome LFHX problems while maintaining heat transfer and air-side pressure drop performance. In this context, heat transfer performances for both LFHX and BTHX were measured experimentally, and the numerical model of the heat exchanger was developed and validated. Then, the geometry model of the BTHX is optimized with five independent design variables. The approximated assisted optimization method is applied with the objectives of maximizing heat transfer performance and minimizing air-side pressure drop. A global sensitivity analysis is performed to analyze the effect of design variables on output performance. A dynamic dip test was performed to evaluate the drainage performance of heat exchangers. The performance of the optimized BTHX is compared with that of the LFHX and discussed the potential of the BTHX for the application to the mobile air conditioning systems.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectAPPROXIMATION-ASSISTED OPTIMIZATION-
dc.subjectCROSS-FLOW-
dc.subjectPERFORMANCE-
dc.subjectFIN-
dc.titleDesign optimization of bare tube heat exchanger for the application to mobile air conditioning systems-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Hoseong-
dc.identifier.doi10.1016/j.applthermaleng.2019.114609-
dc.identifier.scopusid2-s2.0-85075500593-
dc.identifier.wosid000503314300076-
dc.identifier.bibliographicCitationAPPLIED THERMAL ENGINEERING, v.165-
dc.relation.isPartOfAPPLIED THERMAL ENGINEERING-
dc.citation.titleAPPLIED THERMAL ENGINEERING-
dc.citation.volume165-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMechanics-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.relation.journalWebOfScienceCategoryMechanics-
dc.subject.keywordPlusAPPROXIMATION-ASSISTED OPTIMIZATION-
dc.subject.keywordPlusCROSS-FLOW-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusFIN-
dc.subject.keywordAuthorBare tube heat exchanger-
dc.subject.keywordAuthorLouver fin heat exchanger-
dc.subject.keywordAuthorMobile air conditioning system-
dc.subject.keywordAuthorOptimization-
dc.subject.keywordAuthorDrainage test-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE