Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Accuracy of 3-unit fixed dental prostheses fabricated on 3D-printed casts

Authors
Jang, YeonSim, Ji-YoungPark, Jong-KyoungKim, Woong-ChulKim, Hae-YoungKim, Ji-Hwan
Issue Date
1월-2020
Publisher
MOSBY-ELSEVIER
Citation
JOURNAL OF PROSTHETIC DENTISTRY, v.123, no.1, pp.135 - 142
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF PROSTHETIC DENTISTRY
Volume
123
Number
1
Start Page
135
End Page
142
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/58404
DOI
10.1016/j.prosdent.2018.11.004
ISSN
0022-3913
Abstract
Statement of problem. Three-dimensional (3D)-printed casts are used successfully as diagnostic casts in orthodontics. However, whether 3D-printed casts are sufficiently accurate to be used as definitive casts for fixed dental prostheses (FDPs) is unclear. Purpose. The purpose of this in vitro study was to evaluate the fit of 3-unit FDPs fabricated on 3D-printed casts made by digital light processing and to investigate the clinical applicability of 3D printing. Material and methods. A master model was fabricated from epoxy resin. Stone casts were made from dual viscosity impressions (conventional stone cast [CS] group, n=10). The 3D-printed casts were fabricated using a 3D printer after obtaining digital virtual casts by digital scans (3D-printed cast [3DP] group, n=10). All FDPs were fabricated with a 5-axis milling machine. The master model and intaglio surface of the milled FDPs was superimposed using 3D analysis software to measure the accuracy. Two-way ANOVA was performed to identify a significant difference between the groups (3DP and CS) and sides (pontic side, nonpontic side) and their interactive effects (alpha=.05). The Tukey honestly significant difference test was used for post hoc analysis. Results. Two-way ANOVA showed significant differences between the 2 groups (3DP and CS) in the marginal and internal root mean square (RMS) values (P<.001). However, no significant difference was found in the marginal RMS values (P-.762) between the pontic and nonpontic sides. The 3DP showed significantly higher RMS values than the CS (P<.001). Conclusions. The fit of FDPs produced from 3D-printed casts was inferior to that of conventional stone casts; however, all FDPs showed clinically acceptable accuracy. These results suggest that 3D-printed casts have clinical applicability but that further improvement of the 3D printer is necessary for their application in prosthodontics.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hae Young photo

Kim, Hae Young
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE