Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

디지털 광 조명 방식으로 제작한 임시 크라운의 세척 시간에 따른3차원 적합도 평가

Full metadata record
DC Field Value Language
dc.contributor.author이범일-
dc.contributor.author유승규-
dc.contributor.author유승민-
dc.contributor.author김지환-
dc.date.accessioned2021-08-31T17:04:11Z-
dc.date.available2021-08-31T17:04:11Z-
dc.date.created2021-06-17-
dc.date.issued2020-
dc.identifier.issn1229-3954-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/59505-
dc.description.abstractPurpose: This study aimed to compare three-dimensional adaptation with the rinsing time ofthe temporary crown produced using the digital light processing method. Methods: The maxillary right first molar abutment was scanned with a dental scanner. Atemporary crown was designed with the scanned abutment. The designed crown was madeof 10 temporary crowns using a digital light processing printer. The crowns were divided intothe 5-minute and 10-minute rinsing groups; 5 temporary crown washes were performed foreach group. In order to obtain the internal data, each group was scanned for a temporarycrown. The three-dimensional fit was measured by superimposing the scanned internal surfacedata and the abutment data. The average comparison of three-dimensional adaptationwas analyzed using the Mann–Whitney U test. Results: The 5-minute rinsing group showed a significantly higher adaptation of 71.42±3.08μm as compared to the 10-minute rinsing group (67.52±0.92 μm) (p<0.05). Conclusion: When making a temporary crown with a digital light processing method, a rinsingtime of 10 minutes is appropriate.-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한치과기공학회-
dc.title디지털 광 조명 방식으로 제작한 임시 크라운의 세척 시간에 따른3차원 적합도 평가-
dc.title.alternativeComparison of three-dimensional adaptation as per the rinsing time of temporary crown manufactured using a digital light processing printer-
dc.typeArticle-
dc.contributor.affiliatedAuthor김지환-
dc.identifier.doi10.14347/jtd.2020.42.4.334-
dc.identifier.bibliographicCitation대한치과기공학회지, v.42, no.4, pp.334 - 340-
dc.relation.isPartOf대한치과기공학회지-
dc.citation.title대한치과기공학회지-
dc.citation.volume42-
dc.citation.number4-
dc.citation.startPage334-
dc.citation.endPage340-
dc.type.rimsART-
dc.identifier.kciidART002671255-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorAdaptation-
dc.subject.keywordAuthorAdditive manufacturing-
dc.subject.keywordAuthorDigital light processing-
dc.subject.keywordAuthorProvisional crown-
dc.subject.keywordAuthorVat photopolymerization-
dc.subject.keywordAuthor.-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE