유리섬유 보강재를 삽입한 하악 레진의치 인상면의 정밀성 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김동연 | - |
dc.contributor.author | 양천승 | - |
dc.contributor.author | 이광영 | - |
dc.contributor.author | 김지환 | - |
dc.date.accessioned | 2021-08-31T17:05:19Z | - |
dc.date.available | 2021-08-31T17:05:19Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2020 | - |
dc.identifier.issn | 1229-3954 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/59516 | - |
dc.description.abstract | Purpose: This study is to compare and analyze the precision of glass fiber resin dentures. Methods: A lower edentulous model was prepared. Ten study models were produced using Type Ⅳ stone. Ten wax lower resin dentures containing artificial teeth were prepared. The lower wax denture was buried with plaster and deflasking was performed to remove the wax. Five conventional lower resin dentures and five glass fiber lower resin dentures were produced. The scanning spray was coated on the impression surface and then scanned. Independent sample t-test were performed using statistical software. Results: In the color different map, which is a qualitative evaluation, the green area of the precision of the conventional lower resin denture occupied the whole. The glass fiber conventional resin dentures had many negative and positive area. In quantitative evaluation, the RMS of conventional lower resin was 89.83 μm and that of fiberglass resin was 224.92 μm. The two groups showed statistically significant differences (p<0.05). Conclusion: Conventional lower resin dentures were superior in precision, and glass fiber resin dentures would have to improve the process. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 대한치과기공학회 | - |
dc.title | 유리섬유 보강재를 삽입한 하악 레진의치 인상면의 정밀성 평가 | - |
dc.title.alternative | Precision evaluation of impression surface of lower complete dentures reinforced with glass fiber | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 김지환 | - |
dc.identifier.doi | 10.14347/kadt.2020.42.1.27 | - |
dc.identifier.bibliographicCitation | 대한치과기공학회지, v.42, no.1, pp.27 - 33 | - |
dc.relation.isPartOf | 대한치과기공학회지 | - |
dc.citation.title | 대한치과기공학회지 | - |
dc.citation.volume | 42 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 27 | - |
dc.citation.endPage | 33 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002573850 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Complete denture | - |
dc.subject.keywordAuthor | Glass fiber | - |
dc.subject.keywordAuthor | PMMA | - |
dc.subject.keywordAuthor | Precision | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.