IEC 60079-10-1 edition 2.0에 의한 방폭 설계 한계점 보완 방법에 관한 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 최재영 | - |
dc.contributor.author | 변상훈 | - |
dc.date.accessioned | 2021-08-31T17:18:06Z | - |
dc.date.available | 2021-08-31T17:18:06Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2020 | - |
dc.identifier.issn | 1229-6783 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/59633 | - |
dc.description.abstract | IEC 60079-10-1 edition 2.0, the global standard for hazardous area classification, was newly revised in 2015. There are many differences compared to the previous edition 1.0 version, first released in 2008, so it has caused confusion in the industry. In case of edition 1.0, the hazardous area extent can be derived through the mathematical formula, but in case of edition 2.0, there was the problem that the exact hazardous area extent was not known because of the mathematical formula of the plot for applying the hazardous area extent was not presented. In this study, we converted the plot introduced in edition 2.0 to CAD format and derived the plot as the mathematical equations. Through this, we suggest the hazardous area extent formula of three states (heavy gas, diffusive, jet). As the IEC committee did not provide the mathematical formula of the hazardous area extent according to the release characteristic, it is impossible to apply the exact hazardous area extent. In this study, a mathematical approach was derived for the plot introduced in edition 2.0, which can reduce the confusion of the applying hazardous area extent. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 대한안전경영과학회 | - |
dc.title | IEC 60079-10-1 edition 2.0에 의한 방폭 설계 한계점 보완 방법에 관한 연구 | - |
dc.title.alternative | A Study on Complementary Method for Hazardous Area Extent by IEC 60079-10-1 Edition 2.0 | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 변상훈 | - |
dc.identifier.bibliographicCitation | 대한안전경영과학회지, v.22, no.2, pp.73 - 82 | - |
dc.relation.isPartOf | 대한안전경영과학회지 | - |
dc.citation.title | 대한안전경영과학회지 | - |
dc.citation.volume | 22 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 73 | - |
dc.citation.endPage | 82 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002604710 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | Hazardous Area Classification | - |
dc.subject.keywordAuthor | IEC 60079-10-1 | - |
dc.subject.keywordAuthor | Characteristic of Release | - |
dc.subject.keywordAuthor | Process Safety | - |
dc.subject.keywordAuthor | Explosive Atmosphere | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.