Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The Effect of Strict Volume Control Assessed by Repeated Bioimpedance Spectroscopy on Cardiac Function in Peritoneal Dialysis Patients

Full metadata record
DC Field Value Language
dc.contributor.authorHong, Yu Ah-
dc.contributor.authorYoon, Hye Eun-
dc.contributor.authorChoi, Bum Soon-
dc.contributor.authorShin, Seok Joon-
dc.contributor.authorKim, Yong-Soo-
dc.contributor.authorLee, So Young-
dc.contributor.authorLee, Sang-Ho-
dc.contributor.authorKim, Su Hyun-
dc.contributor.authorLee, Eun Young-
dc.contributor.authorShin, Sug Kyun-
dc.contributor.authorKwon, Young Joo-
dc.contributor.authorKim, Jeong Ho-
dc.contributor.authorChang, Yoon Kyung-
dc.contributor.authorKim, Suk Young-
dc.contributor.authorKim, Ji Eun-
dc.contributor.authorAhn, Shin Young-
dc.contributor.authorKo, Gang Jee-
dc.date.accessioned2021-08-31T23:00:52Z-
dc.date.available2021-08-31T23:00:52Z-
dc.date.created2021-06-18-
dc.date.issued2019-11-27-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/61538-
dc.description.abstractAdequate fluid management plays an important role in decreasing cardiovascular risk in peritoneal dialysis (PD) patients. We evaluated whether strict volume control monitored by bioimpedance spectroscopy (BIS) affects cardiac function in PD patients. This study is a secondary analysis of a multicentre, prospective, randomized, controlled trial. Fluid overload was assessed by the average overhydration/extracellular water (OH/ECW) at baseline, 6 months and 12 months. Patients were categorized as time-averaged overhydrated (TA-OH/ECW >= 15%) or normohydrated (TA-OH/ECW <15%), and echocardiographic parameters were compared between groups. Among a total of 151 patients, 120 patients exhibited time-averaged normohydration. Time-averaged overhydrated patients had a significantly higher left atrial (LA) diameter and E/e' ratio and a lower left ventricular (LV) ejection fraction at 12 months than time-averaged normohydrated patients. LA diameter, end-systolic volume and end-diastolic volume were decreased at 12 months compared to baseline in time-averaged normohydrated patients only. TA-OH/ECW was independently associated with ejection fraction at 12 months (beta = -0.190; p = 0.010). TA-OH/ECW, but not OH/ECW at 12 months, was an independent risk factor for LV dysfunction (odds ratio 4.020 [95% confidence interval 1.285-12.573]). Overhydration status based on repeated BIS measurements is an independent predictor of LV systolic function in PD patients.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherNATURE PUBLISHING GROUP-
dc.subjectLEFT-VENTRICULAR HYPERTROPHY-
dc.subjectCHRONIC KIDNEY-DISEASE-
dc.subjectGUIDED FLUID MANAGEMENT-
dc.subjectBODY-COMPOSITION-
dc.subjectHEMODIALYSIS-PATIENTS-
dc.subjectPULSE PRESSURE-
dc.subjectASSOCIATION-
dc.subjectMORTALITY-
dc.subjectOVERHYDRATION-
dc.subjectTRANSPORT-
dc.titleThe Effect of Strict Volume Control Assessed by Repeated Bioimpedance Spectroscopy on Cardiac Function in Peritoneal Dialysis Patients-
dc.typeArticle-
dc.contributor.affiliatedAuthorKwon, Young Joo-
dc.contributor.affiliatedAuthorAhn, Shin Young-
dc.contributor.affiliatedAuthorKo, Gang Jee-
dc.identifier.doi10.1038/s41598-019-53792-0-
dc.identifier.scopusid2-s2.0-85075616309-
dc.identifier.wosid000499179500001-
dc.identifier.bibliographicCitationSCIENTIFIC REPORTS, v.9-
dc.relation.isPartOfSCIENTIFIC REPORTS-
dc.citation.titleSCIENTIFIC REPORTS-
dc.citation.volume9-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusLEFT-VENTRICULAR HYPERTROPHY-
dc.subject.keywordPlusCHRONIC KIDNEY-DISEASE-
dc.subject.keywordPlusGUIDED FLUID MANAGEMENT-
dc.subject.keywordPlusBODY-COMPOSITION-
dc.subject.keywordPlusHEMODIALYSIS-PATIENTS-
dc.subject.keywordPlusPULSE PRESSURE-
dc.subject.keywordPlusASSOCIATION-
dc.subject.keywordPlusMORTALITY-
dc.subject.keywordPlusOVERHYDRATION-
dc.subject.keywordPlusTRANSPORT-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ko, Gang Jee photo

Ko, Gang Jee
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE