Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Theory of three-pulse photon echo spectroscopy with dual frequency combs

Full metadata record
DC Field Value Language
dc.contributor.authorJeon, Jonggu-
dc.contributor.authorKim, JunWoo-
dc.contributor.authorYoon, Tai Hyun-
dc.contributor.authorCho, Minhaeng-
dc.date.accessioned2021-09-01T00:32:47Z-
dc.date.available2021-09-01T00:32:47Z-
dc.date.created2021-06-18-
dc.date.issued2019-11-01-
dc.identifier.issn0740-3224-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/61947-
dc.description.abstractA theoretical analysis is carried out for the recently developed three-pulse photon echo spectroscopy employing dual frequency combs (DFC) as the light sources. In this method, the molecular sample interacts with three pulse trains derived from the DFC, and the generated third-order signal is displayed as a two-dimensional (2D) spectrum that depends on the waiting time introduced by employing the asynchronous optical sampling method. Through the analysis of the heterodyne-detected signal interferogram using a local oscillator derived from one of the optical frequency combs, we show that the 2D spectrum closely matches the spectrum expected from a conventional approach with four pulses derived from a single femtosecond laser pulse, and the waiting time between the second and third field-matter interactions is given by the down-converted detection time of the interferogram. The theoretical result is applied to a two-level model system with solvation effect described by solvatochromic spectral density. The model 2D spectrum reproduces spectral features such as the loss of frequency correlation, dephasing, and spectral shift as a function of the population time. We anticipate that the present theory will be the general framework for quantitative descriptions of DFC-based nonlinear optical spectroscopy. (C) 2019 Optical Society of America-
dc.languageEnglish-
dc.language.isoen-
dc.publisherOPTICAL SOC AMER-
dc.titleTheory of three-pulse photon echo spectroscopy with dual frequency combs-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoon, Tai Hyun-
dc.contributor.affiliatedAuthorCho, Minhaeng-
dc.identifier.doi10.1364/JOSAB.36.003196-
dc.identifier.scopusid2-s2.0-85076129740-
dc.identifier.wosid000493941200037-
dc.identifier.bibliographicCitationJOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, v.36, no.11, pp.3196 - 3208-
dc.relation.isPartOfJOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS-
dc.citation.titleJOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS-
dc.citation.volume36-
dc.citation.number11-
dc.citation.startPage3196-
dc.citation.endPage3208-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOptics-
dc.relation.journalWebOfScienceCategoryOptics-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Physics > 1. Journal Articles
College of Science > Department of Chemistry > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Min haeng photo

Cho, Min haeng
이과대학 (화학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE