Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Standardized, musculoskeletal ultrasonographic reference values for healthy Korean adults

Authors
Kim, Hyun-SookKim, Hae-RimKim, Bo YoungKim, Yun SungJung, Young OkChoi, Sung JaeKim, Hyun-OkHwang, JiwonLee, SunggunKim, Hyoun-AhBang, So YoungChai, Ji-YoungPark, Sung-HoonYoon, Chong-Hyeon
Issue Date
11월-2019
Publisher
KOREAN ASSOC INTERNAL MEDICINE
Keywords
Musculoskeletal; Ultrasonography; Reference standards; Education
Citation
KOREAN JOURNAL OF INTERNAL MEDICINE, v.34, no.6, pp.1372 - 1380
Indexed
SCIE
SCOPUS
KCI
Journal Title
KOREAN JOURNAL OF INTERNAL MEDICINE
Volume
34
Number
6
Start Page
1372
End Page
1380
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/62072
DOI
10.3904/kjim.2016.397
ISSN
1226-3303
Abstract
Background/Aims: To define standard reference values for musculoskeletal ultrasonography (MSUS) in Korea. Methods: A total of 251 healthy adults were recruited for this study. Ultrasonography was performed by experienced rheumatologists who had undergone four appropriate training programs in Korea. A General Electric LOGIQ electronic ultrasound device fitted with a 12 MHz linear transducer was employed. Mean values t standard deviations (SDs) were defined as standard reference values. Intraclass correlation coefficients was employed to evaluate the extent of inter- and intraobserver agreement when MSUS measurements were made. Results: The 251 study participants included 122 males. Mean subject age was 28.6 years. The average bone-to-capsule distance of the right-side second and third metacarpophalangeal (MCP) joints were 0.68 and 0.72 mm respectively, and those of the left-side joints 0.62 and 0.68 mm. The cartilage thicknesses of the right-side second and third MCP joints were 0.55 and 0.55 mm, and those of the left-side joints were 0.55 and 0.56 mm, respectively. The bone-to-capsule distances of the right and left wrists were 0.80 and 0.82 mm. In 12.4% of participants (31/251), the erosion score of the humeral head was 1.71. In the right-side knee joint, mean cartilage thicknesses of the medial and lateral condyles were 1.86 and 2.03 mm in longitudinal scans. High overall interobserver agreement was evident after appropriate training that included instruction on standard MSUS methodology. Conclusions: We defined standard reference values for MSUS in healthy Korean adults. The reliabilities of interobserver agreements were high after appropriate training program.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE