Fragment specific fixation technique using 2.7 mm VA LCP for comminuted posterior wall acetabular fractures: a novel surgical technique
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, Jae-Woo | - |
dc.contributor.author | Chung, Hoe Jeong | - |
dc.contributor.author | Kim, Beom-Soo | - |
dc.contributor.author | Yeo, Do-Hyun | - |
dc.contributor.author | Song, Jong-Hyeop | - |
dc.contributor.author | Oh, Chang-Wug | - |
dc.contributor.author | Mauffrey, Cyril | - |
dc.contributor.author | Cho, Won-Tae | - |
dc.contributor.author | Oh, Jong-Keon | - |
dc.date.accessioned | 2021-09-01T01:26:28Z | - |
dc.date.available | 2021-09-01T01:26:28Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2019-11 | - |
dc.identifier.issn | 0936-8051 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/62092 | - |
dc.description.abstract | Purpose The purposes of the study were to introduce surgical technique of fragment-specific fixation technique using multiple 2.7-mm variable-angle locking compression plates (VA LCPs) in comminuted posterior wall acetabular fractures and reported its clinical results. Patients and methods Among the 68 patients, 23 with comminuted posterior wall factures with >= 3 fragments in the CT scan and no column involvement with a minimum follow-up duration of 12 months were enrolled in this study. We evaluated the clinical results after the treatment of comminuted posterior wall acetabular fractures via the fragment-specific fixation technique using 2.7-mm variable-angle locking compression plates (VA LCPs) retrospectively. Results The average duration of follow-up was 26.8 months. Anatomical reduction was achieved in eighteen patients. Imperfect reduction was achieved in five patients. 22 patients achieved fracture union and one patient underwent revision surgery owing to acute postoperative infection. There were no complications, including loss of reduction, fixative failures, sciatic nerve palsy, heterotopic ossification, and early posttraumatic arthritis among 22 patients. The average functional outcome was measured as 'very good'. Conclusion Fragment-specific fixation technique using 2.7-mm VA LCPs for comminuted posterior wall acetabular fractures could be an acceptable alternative means of surgical fixation. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER | - |
dc.subject | SPRING PLATES | - |
dc.subject | OPERATIVE TREATMENT | - |
dc.subject | INTERNAL-FIXATION | - |
dc.subject | RECONSTRUCTION | - |
dc.subject | REDUCTION | - |
dc.subject | ACCURACY | - |
dc.title | Fragment specific fixation technique using 2.7 mm VA LCP for comminuted posterior wall acetabular fractures: a novel surgical technique | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Cho, Jae-Woo | - |
dc.contributor.affiliatedAuthor | Oh, Jong-Keon | - |
dc.identifier.doi | 10.1007/s00402-019-03236-1 | - |
dc.identifier.scopusid | 2-s2.0-85069686200 | - |
dc.identifier.wosid | 000491055800012 | - |
dc.identifier.bibliographicCitation | ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, v.139, no.11, pp.1587 - 1597 | - |
dc.relation.isPartOf | ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY | - |
dc.citation.title | ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY | - |
dc.citation.volume | 139 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 1587 | - |
dc.citation.endPage | 1597 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Orthopedics | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Orthopedics | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | SPRING PLATES | - |
dc.subject.keywordPlus | OPERATIVE TREATMENT | - |
dc.subject.keywordPlus | INTERNAL-FIXATION | - |
dc.subject.keywordPlus | RECONSTRUCTION | - |
dc.subject.keywordPlus | REDUCTION | - |
dc.subject.keywordPlus | ACCURACY | - |
dc.subject.keywordAuthor | Fixation | - |
dc.subject.keywordAuthor | Posterior wall acetabular fracture | - |
dc.subject.keywordAuthor | Comminuted | - |
dc.subject.keywordAuthor | Fragment specific | - |
dc.subject.keywordAuthor | Variable-angle locking plate | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.