A new blind source separation framework for signal analysis and artifact rejection in functional Near-Infrared Spectroscopy
DC Field | Value | Language |
---|---|---|
dc.contributor.author | von Luehmann, Alexander | - |
dc.contributor.author | Boukouvalas, Zois | - |
dc.contributor.author | Mueller, Klaus-Robert | - |
dc.contributor.author | Adali, Tulay | - |
dc.date.accessioned | 2021-09-01T02:46:15Z | - |
dc.date.available | 2021-09-01T02:46:15Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2019-10-15 | - |
dc.identifier.issn | 1053-8119 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/62514 | - |
dc.description.abstract | In the analysis of functional Near-Infrared Spectroscopy (fNIRS) signals from real-world scenarios, artifact rejection is essential. However, currently there exists no gold-standard. Although a plenitude of methodological approaches implicitly assume the presence of latent processes in the signals, elaborate Blind-Source-Separation methods have rarely been applied. A reason are challenging characteristics such as Non-instantaneous and non-constant coupling, correlated noise and statistical dependencies between signal components. We present a novel suitable BSS framework that tackles these issues by incorporating A) Independent Component Analysis methods that exploit both higher order statistics and sample dependency, B) multimodality, i.e., fNIRS with accelerometer signals, and C) Canonical-Correlation Analysis with temporal embedding. This enables analysis of signal components and rejection of motion-induced physiological hemodynamic artifacts that would otherwise be hard to identify. We implement a method for Blind Source Separation and Accelerometer based Artifact Rejection and Detection (BLISSA(2)RD). It allows the analysis of a novel n-back based cognitive workload paradigm in freely moving subjects, that is also presented in this manuscript. We evaluate on the corresponding data set and simulated ground truth data, making use of metrics based on 1st and 2nd order statistics and SNR and compare with three established methods: PCA, Spline and Wavelet-based artifact removal. Across 17 subjects, the method is shown to reduce movement induced artifacts by up to two orders of magnitude, improves the SNR of continuous hemodynamic signals in single channels by up to 10 dB, and significantly outperforms conventional methods in the extraction of simulated Hemodynamic Response Functions from strongly contaminated data. The framework and methods presented can serve as an introduction to a new type of multivariate methods for the analysis of fNIRS signals and as a blueprint for artifact rejection in complex environments beyond the applied paradigm. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ACADEMIC PRESS INC ELSEVIER SCIENCE | - |
dc.subject | INDEPENDENT COMPONENT ANALYSIS | - |
dc.subject | MOVEMENT ARTIFACTS | - |
dc.subject | TIME-SERIES | - |
dc.subject | NIRS | - |
dc.subject | REMOVAL | - |
dc.subject | HEALTH | - |
dc.subject | TISSUE | - |
dc.subject | ALGORITHMS | - |
dc.subject | ACTIVATION | - |
dc.subject | ROBUST | - |
dc.title | A new blind source separation framework for signal analysis and artifact rejection in functional Near-Infrared Spectroscopy | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Mueller, Klaus-Robert | - |
dc.identifier.doi | 10.1016/j.neuroimage.2019.06.021 | - |
dc.identifier.scopusid | 2-s2.0-85067812680 | - |
dc.identifier.wosid | 000481579300007 | - |
dc.identifier.bibliographicCitation | NEUROIMAGE, v.200, pp.72 - 88 | - |
dc.relation.isPartOf | NEUROIMAGE | - |
dc.citation.title | NEUROIMAGE | - |
dc.citation.volume | 200 | - |
dc.citation.startPage | 72 | - |
dc.citation.endPage | 88 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Neurosciences & Neurology | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Neurosciences | - |
dc.relation.journalWebOfScienceCategory | Neuroimaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | INDEPENDENT COMPONENT ANALYSIS | - |
dc.subject.keywordPlus | MOVEMENT ARTIFACTS | - |
dc.subject.keywordPlus | TIME-SERIES | - |
dc.subject.keywordPlus | NIRS | - |
dc.subject.keywordPlus | REMOVAL | - |
dc.subject.keywordPlus | HEALTH | - |
dc.subject.keywordPlus | TISSUE | - |
dc.subject.keywordPlus | ALGORITHMS | - |
dc.subject.keywordPlus | ACTIVATION | - |
dc.subject.keywordPlus | ROBUST | - |
dc.subject.keywordAuthor | fNIRS | - |
dc.subject.keywordAuthor | Neuroimaging in motion | - |
dc.subject.keywordAuthor | Blind source separation | - |
dc.subject.keywordAuthor | Entropy rate bound minimization | - |
dc.subject.keywordAuthor | Multimodality | - |
dc.subject.keywordAuthor | Machine learning | - |
dc.subject.keywordAuthor | Artifact removal | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.