Enhancing sensorimotor BCI performance with assistive afferent activity: An online evaluation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Vidaurre, C. | - |
dc.contributor.author | Ramos Murguialday, A. | - |
dc.contributor.author | Haufe, S. | - |
dc.contributor.author | Gomez, M. | - |
dc.contributor.author | Mueller, K-R | - |
dc.contributor.author | Nikulin, V. V. | - |
dc.date.accessioned | 2021-09-01T04:44:57Z | - |
dc.date.available | 2021-09-01T04:44:57Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2019-10-01 | - |
dc.identifier.issn | 1053-8119 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/62562 | - |
dc.description.abstract | An important goal in Brain-Computer Interfacing (BCI) is to find and enhance procedural strategies for users for whom BCI control is not sufficiently accurate. To address this challenge, we conducted offline analyses and online experiments to test whether the classification of different types of motor imagery could be improved when the training of the classifier was performed on the data obtained with the assistive muscular stimulation below the motor threshold. 10 healthy participants underwent three different types of experimental conditions: a) Motor imagery (MI) of hands and feet b) sensory threshold neuromuscular electrical stimulation (STM) of hands and feet while resting and c) sensory threshold neuromuscular electrical stimulation during performance of motor imagery (BOTH). Also, another group of 10 participants underwent conditions a) and c). Then, online experiments with 15 users were performed. These subjects received neurofeedback during MI using classifiers calibrated either on MI or BOTH data recorded in the same experiment. Offline analyses showed that decoding MI alone using a classifier based on BOTH resulted in a better BCI accuracy compared to using a classifier based on MI alone. Online experiments confirmed accuracy improvement of MI alone being decoded with the classifier trained on BOTH data. In addition, we observed that the performance in MI condition could be predicted on the basis of a more pronounced connectivity within sensorimotor areas in the frequency bands providing the best performance in BOTH. These finding might offer a new avenue for training SMR-based BCI systems particularly for users having difficulties to achieve efficient BCI control. It might also be an alternative strategy for users who cannot perform real movements but still have remaining afferent pathways (e.g., ALS and stroke patients). | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ACADEMIC PRESS INC ELSEVIER SCIENCE | - |
dc.subject | BRAIN-COMPUTER INTERFACE | - |
dc.subject | EEG SOURCE LOCALIZATION | - |
dc.subject | FUNCTIONAL CONNECTIVITY | - |
dc.subject | STIMULATION | - |
dc.subject | DESYNCHRONIZATION | - |
dc.subject | REORGANIZATION | - |
dc.subject | DYNAMICS | - |
dc.subject | VOLUME | - |
dc.subject | STATE | - |
dc.title | Enhancing sensorimotor BCI performance with assistive afferent activity: An online evaluation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Mueller, K-R | - |
dc.identifier.doi | 10.1016/j.neuroimage.2019.05.074 | - |
dc.identifier.scopusid | 2-s2.0-85067109507 | - |
dc.identifier.wosid | 000478780200035 | - |
dc.identifier.bibliographicCitation | NEUROIMAGE, v.199, pp.375 - 386 | - |
dc.relation.isPartOf | NEUROIMAGE | - |
dc.citation.title | NEUROIMAGE | - |
dc.citation.volume | 199 | - |
dc.citation.startPage | 375 | - |
dc.citation.endPage | 386 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Neurosciences & Neurology | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Neurosciences | - |
dc.relation.journalWebOfScienceCategory | Neuroimaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | BRAIN-COMPUTER INTERFACE | - |
dc.subject.keywordPlus | EEG SOURCE LOCALIZATION | - |
dc.subject.keywordPlus | FUNCTIONAL CONNECTIVITY | - |
dc.subject.keywordPlus | STIMULATION | - |
dc.subject.keywordPlus | DESYNCHRONIZATION | - |
dc.subject.keywordPlus | REORGANIZATION | - |
dc.subject.keywordPlus | DYNAMICS | - |
dc.subject.keywordPlus | VOLUME | - |
dc.subject.keywordPlus | STATE | - |
dc.subject.keywordAuthor | Motor imagery (MI) | - |
dc.subject.keywordAuthor | Sensory threshold neuromuscular electrical | - |
dc.subject.keywordAuthor | stimulation (STM) | - |
dc.subject.keywordAuthor | Afferent patterns | - |
dc.subject.keywordAuthor | Efferent patterns | - |
dc.subject.keywordAuthor | Brain-computer interfacing (BCI) inefficiency | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.