dc.description.abstract | Sample delivery using injectors is widely used in serial crystallography (SX) and has significantly contributed to the determination of crystal structures at room temperature. However, sophisticated injector nozzle fabrication methods and sample delivery operations have made it difficult for ordinary users to access the SX research. Herein, a simple and easily accessible sample delivery method for SX experiments is introduced, that uses a viscous medium, commercially available syringe and syringe pump. The syringe containing the lysozyme crystals embedded in lipidic cubic phase (LCP) or polyacrylamide (PAM) delivery media was connected to a needle having an inner diameter of 168 mu m, after which it was installed on a syringe pump. By driving the syringe pump, the syringe plunger was pushed and the crystal sample was delivered to the X-ray beam position in a stable manner. Using this system, the room-temperature crystal structures of lysozyme embedded in LCP and PAM at 1.56 angstrom and 1.75 angstrom, respectively, were determined. This straightforward syringe pump-based sample delivery system can be utilized in SX. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | INT UNION CRYSTALLOGRAPHY | - |
dc.title | Sample delivery using viscous media, a syringe andasyringe pump for serial crystallography | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Nam, Ki Hyun | - |
dc.identifier.doi | 10.1107/S160057751900897X | - |
dc.identifier.scopusid | 2-s2.0-85071774344 | - |
dc.identifier.wosid | 000484666200048 | - |
dc.identifier.bibliographicCitation | JOURNAL OF SYNCHROTRON RADIATION, v.26, pp.1815 - 1819 | - |
dc.relation.isPartOf | JOURNAL OF SYNCHROTRON RADIATION | - |
dc.citation.title | JOURNAL OF SYNCHROTRON RADIATION | - |
dc.citation.volume | 26 | - |
dc.citation.startPage | 1815 | - |
dc.citation.endPage | 1819 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalResearchArea | Optics | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Optics | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordAuthor | serial crystallography | - |
dc.subject.keywordAuthor | sample delivery | - |
dc.subject.keywordAuthor | syringe pumps | - |
dc.subject.keywordAuthor | viscous media | - |
dc.subject.keywordAuthor | lipidic cubic phase | - |
dc.subject.keywordAuthor | polyacrylamide | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.