Agreement and Reproducibility of Proton Density Fat Fraction Measurements Using Commercial MR Sequences Across Different Platforms A Multivendor, Multi-Institutional Phantom Experiment
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jang, Jong Keon | - |
dc.contributor.author | Lee, Seung Soo | - |
dc.contributor.author | Kim, Bohyun | - |
dc.contributor.author | Cho, Eun-Suk | - |
dc.contributor.author | Kim, Yeong Jae | - |
dc.contributor.author | Byun, Jae Ho | - |
dc.contributor.author | Park, Beom Jin | - |
dc.contributor.author | Kim, So Yeon | - |
dc.contributor.author | Kim, Jin Hee | - |
dc.date.accessioned | 2021-09-01T10:09:26Z | - |
dc.date.available | 2021-09-01T10:09:26Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2019-08 | - |
dc.identifier.issn | 0020-9996 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/63651 | - |
dc.description.abstract | Objectives The aim of this study was to evaluate the agreement and reproducibility of proton density fat fraction (PDFF) measurements using commercial magnetic resonance (MR) sequences across different imagers, vendors, and field strengths via a phantom experiment. Materials and Methods Eleven fat-water emulsion phantoms of varying fat proportions (ie, 0-50 weight%) were constructed. Phantom PDFFs were estimated using commercial chemical shift-based MR imaging sequences with Siemens 1.5 T and 3.0 T, Philips 3.0 T, and GE 1.5 T and 3.0 T imagers, and MR spectroscopic sequences (HISTO) with Siemens 1.5 T and 3.0 T imagers. Agreement among the estimated PDFF values between commercial sequences was evaluated using Bland-Altman analysis. Reproducibility of the PDFF measurements across commercial sequences was evaluated using the reproducibility coefficient. The test-retest repeatability of the PDFF measurements was evaluated using the repeatability coefficient. Results The repeatability coefficient of the PDFF measurements was 0.31% to 1.58% for the absolute PDFF value for commercial sequences. Statistically significant biases in the estimated PDFF were noted in 19 of 21 pairwise comparisons of commercial sequences (range of mean biases, -4.48% to 8.15% for the absolute PDFF value). The reproducibility coefficient of PDFF measurements was 9.0% for the absolute PDFF value over all commercial sequences and 10.6% for the absolute PDFF value over all chemical shift-based MR imaging sequences. Conclusions The measurement of the PDFF is highly repeatable with commercial MR sequences but is not reproducible across different sequences, imager vendors, and field strengths. The use of the same sequence and imager is therefore recommended for the longitudinal follow-up of hepatic steatosis using commercial MR sequences for PDFF measurements. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | LIPPINCOTT WILLIAMS & WILKINS | - |
dc.subject | QUANTITATIVE IMAGING BIOMARKERS | - |
dc.subject | MAGNETIC-RESONANCE-SPECTROSCOPY | - |
dc.subject | LIVER FAT | - |
dc.subject | STATISTICAL-METHODS | - |
dc.subject | QUANTIFICATION | - |
dc.subject | DISEASE | - |
dc.subject | PREVALENCE | - |
dc.subject | STEATOSIS | - |
dc.subject | ACCURACY | - |
dc.subject | 1.5T | - |
dc.title | Agreement and Reproducibility of Proton Density Fat Fraction Measurements Using Commercial MR Sequences Across Different Platforms A Multivendor, Multi-Institutional Phantom Experiment | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Park, Beom Jin | - |
dc.identifier.doi | 10.1097/RLI.0000000000000561 | - |
dc.identifier.scopusid | 2-s2.0-85069174891 | - |
dc.identifier.wosid | 000475956100009 | - |
dc.identifier.bibliographicCitation | INVESTIGATIVE RADIOLOGY, v.54, no.8, pp.517 - 523 | - |
dc.relation.isPartOf | INVESTIGATIVE RADIOLOGY | - |
dc.citation.title | INVESTIGATIVE RADIOLOGY | - |
dc.citation.volume | 54 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 517 | - |
dc.citation.endPage | 523 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | QUANTITATIVE IMAGING BIOMARKERS | - |
dc.subject.keywordPlus | MAGNETIC-RESONANCE-SPECTROSCOPY | - |
dc.subject.keywordPlus | LIVER FAT | - |
dc.subject.keywordPlus | STATISTICAL-METHODS | - |
dc.subject.keywordPlus | QUANTIFICATION | - |
dc.subject.keywordPlus | DISEASE | - |
dc.subject.keywordPlus | PREVALENCE | - |
dc.subject.keywordPlus | STEATOSIS | - |
dc.subject.keywordPlus | ACCURACY | - |
dc.subject.keywordPlus | 1.5T | - |
dc.subject.keywordAuthor | PDFF | - |
dc.subject.keywordAuthor | commercial MR sequence | - |
dc.subject.keywordAuthor | CS-MRI | - |
dc.subject.keywordAuthor | HISTO | - |
dc.subject.keywordAuthor | reproducibility | - |
dc.subject.keywordAuthor | phantom study | - |
dc.subject.keywordAuthor | hepatic steatosis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.