Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Kyung Hee | - |
dc.contributor.author | Lim, Kun Young | - |
dc.contributor.author | Suh, Young Joo | - |
dc.contributor.author | Hur, Jin | - |
dc.contributor.author | Han, Dae Hee | - |
dc.contributor.author | Kang, Mi-Jin | - |
dc.contributor.author | Choo, Ji Yung | - |
dc.contributor.author | Kim, Cherry | - |
dc.contributor.author | Kim, Jung Im | - |
dc.contributor.author | Yoon, Soon Ho | - |
dc.contributor.author | Lee, Woojoo | - |
dc.contributor.author | Park, Chang Min | - |
dc.date.accessioned | 2021-09-01T10:10:08Z | - |
dc.date.available | 2021-09-01T10:10:08Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2019-08 | - |
dc.identifier.issn | 1229-6929 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/63656 | - |
dc.description.abstract | Objective: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20-99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6-91.7%), 92.5% (95% CI, 91.9-93.1%), 86.5% (95% CI, 85.0-87.9%), 99.2% (95% CI, 99.0-99.4%), and 84.3% (95% CI, 82.7-85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3-9.4%). The independent risk factors for diagnostic failures were lesions <= 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23-2.81), lesion size 1.1-2 cm (1.75; 1.45-2.11), subsolid lesions (1.81; 1.32-2.49), use of fine needle aspiration only (2.43; 1.80-3.28), final diagnosis of benign lesions (2.18; 1.84-2.58), and final diagnosis of lymphomas (10.66; 6.21-18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13-0.75) and conventional CT-guidance (0.55; 0.32-0.94) reduced diagnostic failures. Conclusion: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN RADIOLOGICAL SOC | - |
dc.subject | CONE-BEAM CT | - |
dc.subject | PULMONARY-LESIONS | - |
dc.subject | ASPIRATION BIOPSY | - |
dc.subject | GUIDED BIOPSY | - |
dc.subject | REPEAT BIOPSY | - |
dc.subject | NODULES | - |
dc.subject | EXPERIENCE | - |
dc.subject | CANCER | - |
dc.subject | MM | - |
dc.title | Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Cherry | - |
dc.identifier.doi | 10.3348/kjr.2019.0189 | - |
dc.identifier.scopusid | 2-s2.0-85069834602 | - |
dc.identifier.wosid | 000486903900006 | - |
dc.identifier.bibliographicCitation | KOREAN JOURNAL OF RADIOLOGY, v.20, no.8, pp.1300 - 1310 | - |
dc.relation.isPartOf | KOREAN JOURNAL OF RADIOLOGY | - |
dc.citation.title | KOREAN JOURNAL OF RADIOLOGY | - |
dc.citation.volume | 20 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 1300 | - |
dc.citation.endPage | 1310 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002488403 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | CONE-BEAM CT | - |
dc.subject.keywordPlus | PULMONARY-LESIONS | - |
dc.subject.keywordPlus | ASPIRATION BIOPSY | - |
dc.subject.keywordPlus | GUIDED BIOPSY | - |
dc.subject.keywordPlus | REPEAT BIOPSY | - |
dc.subject.keywordPlus | NODULES | - |
dc.subject.keywordPlus | EXPERIENCE | - |
dc.subject.keywordPlus | CANCER | - |
dc.subject.keywordPlus | MM | - |
dc.subject.keywordAuthor | Image-guided biopsy | - |
dc.subject.keywordAuthor | Sensitivity and specificity | - |
dc.subject.keywordAuthor | Lung neoplasms | - |
dc.subject.keywordAuthor | Multicenter study | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.