Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Kyung Hee-
dc.contributor.authorLim, Kun Young-
dc.contributor.authorSuh, Young Joo-
dc.contributor.authorHur, Jin-
dc.contributor.authorHan, Dae Hee-
dc.contributor.authorKang, Mi-Jin-
dc.contributor.authorChoo, Ji Yung-
dc.contributor.authorKim, Cherry-
dc.contributor.authorKim, Jung Im-
dc.contributor.authorYoon, Soon Ho-
dc.contributor.authorLee, Woojoo-
dc.contributor.authorPark, Chang Min-
dc.date.accessioned2021-09-01T10:10:08Z-
dc.date.available2021-09-01T10:10:08Z-
dc.date.created2021-06-18-
dc.date.issued2019-08-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/63656-
dc.description.abstractObjective: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20-99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6-91.7%), 92.5% (95% CI, 91.9-93.1%), 86.5% (95% CI, 85.0-87.9%), 99.2% (95% CI, 99.0-99.4%), and 84.3% (95% CI, 82.7-85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3-9.4%). The independent risk factors for diagnostic failures were lesions <= 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23-2.81), lesion size 1.1-2 cm (1.75; 1.45-2.11), subsolid lesions (1.81; 1.32-2.49), use of fine needle aspiration only (2.43; 1.80-3.28), final diagnosis of benign lesions (2.18; 1.84-2.58), and final diagnosis of lymphomas (10.66; 6.21-18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13-0.75) and conventional CT-guidance (0.55; 0.32-0.94) reduced diagnostic failures. Conclusion: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN RADIOLOGICAL SOC-
dc.subjectCONE-BEAM CT-
dc.subjectPULMONARY-LESIONS-
dc.subjectASPIRATION BIOPSY-
dc.subjectGUIDED BIOPSY-
dc.subjectREPEAT BIOPSY-
dc.subjectNODULES-
dc.subjectEXPERIENCE-
dc.subjectCANCER-
dc.subjectMM-
dc.titleDiagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Cherry-
dc.identifier.doi10.3348/kjr.2019.0189-
dc.identifier.scopusid2-s2.0-85069834602-
dc.identifier.wosid000486903900006-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, v.20, no.8, pp.1300 - 1310-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.citation.titleKOREAN JOURNAL OF RADIOLOGY-
dc.citation.volume20-
dc.citation.number8-
dc.citation.startPage1300-
dc.citation.endPage1310-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002488403-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusCONE-BEAM CT-
dc.subject.keywordPlusPULMONARY-LESIONS-
dc.subject.keywordPlusASPIRATION BIOPSY-
dc.subject.keywordPlusGUIDED BIOPSY-
dc.subject.keywordPlusREPEAT BIOPSY-
dc.subject.keywordPlusNODULES-
dc.subject.keywordPlusEXPERIENCE-
dc.subject.keywordPlusCANCER-
dc.subject.keywordPlusMM-
dc.subject.keywordAuthorImage-guided biopsy-
dc.subject.keywordAuthorSensitivity and specificity-
dc.subject.keywordAuthorLung neoplasms-
dc.subject.keywordAuthorMulticenter study-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE