Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Airgap Search Coil-Based Detection of Damper Bar Failures in Salient Pole Synchronous Motors

Full metadata record
DC Field Value Language
dc.contributor.authorYun, Jangho-
dc.contributor.authorPark, Sang Wook-
dc.contributor.authorYang, Chanseung-
dc.contributor.authorLee, Sang Bin-
dc.contributor.authorAntonino-Daviu, Jose A.-
dc.contributor.authorSasic, Mladen-
dc.contributor.authorStone, Greg C.-
dc.date.accessioned2021-09-01T13:23:36Z-
dc.date.available2021-09-01T13:23:36Z-
dc.date.created2021-06-19-
dc.date.issued2019-07-
dc.identifier.issn0093-9994-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/64605-
dc.description.abstractDamper bars are often used in high output salient pole synchronous motor (SM) rotors for motor starting and stabilization of performance. Several cases of broken damper bars in the rotor of SMs that lead to motor starting failure and/or forced outage have recently been reported. However, detection of damper bar failures is difficult, since the damper bars are active only under the starting or load transients. Damper bar testing in the field currently relies on off-line visual inspection, and there is no means available for detecting failures on line. In this paper, a new method for detecting damper bar failures based on the analysis of airgap search coil measurements under the starting transient is proposed. Since airgap search coils are being increasingly installed in large SMs for detecting field winding short circuits, the proposed method can be implemented without additional hardware. The effectiveness of the proposed method is verified with two-dimensional finite element analysis and experimental testing on a custom-built 30 kW salient pole SM under controlled fault conditions. It is shown that the proposed method can provide reliable and sensitive detection of broken damper bars whenever the motor is started at low additional cost. The off-line single phase rotation test is also shown to provide reliable monitoring of damper bar condition.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subjectROTOR-
dc.subjectWINDINGS-
dc.titleAirgap Search Coil-Based Detection of Damper Bar Failures in Salient Pole Synchronous Motors-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Sang Bin-
dc.identifier.doi10.1109/TIA.2019.2912148-
dc.identifier.wosid000474562900033-
dc.identifier.bibliographicCitationIEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, v.55, no.4, pp.3640 - 3648-
dc.relation.isPartOfIEEE TRANSACTIONS ON INDUSTRY APPLICATIONS-
dc.citation.titleIEEE TRANSACTIONS ON INDUSTRY APPLICATIONS-
dc.citation.volume55-
dc.citation.number4-
dc.citation.startPage3640-
dc.citation.endPage3648-
dc.type.rimsART-
dc.type.docTypeArticle; Proceedings Paper-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryEngineering, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.subject.keywordPlusROTOR-
dc.subject.keywordPlusWINDINGS-
dc.subject.keywordAuthorAirgap flux-
dc.subject.keywordAuthorcondition monitoring-
dc.subject.keywordAuthorfault diagnostics-
dc.subject.keywordAuthorsalient pole synchronousmotor (SM)-
dc.subject.keywordAuthorsearch coil-
dc.subject.keywordAuthorspectral analysis-
dc.subject.keywordAuthorstarting transient-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sang bin photo

Lee, Sang bin
College of Engineering (School of Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE