Clinical characteristics and rhythm outcome of catheter ablation of hemodynamically corrected valvular atrial fibrillation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Jung Ok | - |
dc.contributor.author | Shim, Jaemin | - |
dc.contributor.author | Lee, Seung-Hyun | - |
dc.contributor.author | Yu, Hee Tae | - |
dc.contributor.author | Kim, Tae-Hoon | - |
dc.contributor.author | Uhm, Jae-Sun | - |
dc.contributor.author | Choi, Jong-Il | - |
dc.contributor.author | Choi, Jae Young | - |
dc.contributor.author | Lee, Moon-Hyung | - |
dc.contributor.author | Kim, Young-Hoon | - |
dc.contributor.author | Chang, Byung-Chul | - |
dc.contributor.author | Pak, Hui-Nam | - |
dc.date.accessioned | 2021-09-01T14:40:30Z | - |
dc.date.available | 2021-09-01T14:40:30Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2019-06 | - |
dc.identifier.issn | 0914-5087 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/65301 | - |
dc.description.abstract | Background: Although the hemodynamic burden and structural substrate contribute to valvular atrial fibrillation (VAF) mechanisms, the role of catheter ablation has rarely been reported. We investigated the clinical characteristics, mapping findings, and long-term rhythm outcomes after catheter ablation of hemodynamically corrected VAF. Methods: We compared 77 patients with VAF (46.8% male, 52.7 +/- 8.8 years old, 46.8% paroxysmal AF, 24.7% with maze procedures) and 2244 patients with non-VAF (NVAF) who underwent catheter ablation. Among the VAF patients, 44 (57.1%) had mechanical valve AF (MV-AF) and 33 (42.9%) underwent a prior mitral valvuloplasty (MVP-AF). We analyzed the catheter ablation rhythm outcomes for MV-AF and MVP-AF. Results: The left atrial (LA) diameter was greater (p < 0.001), LA voltage lower (p < 0.001), and procedure-related complication rate higher (mainly sinus node dysfunction, p = 0.004) for VAF than NVAF. During 70.2 +/- 1.8 months of follow-up, the rhythm outcome of VAF did not significantly differ from that of NVAF after catheter ablation (log rank p = 0.399), even after excluding patients with maze procedures (log rank p = 0.629). The clinical recurrence rates did not differ between the MV-AF and MVP-AF groups (log rank p = 0.244), or between patients with prior maze procedures and those without (log rank p = 0.651). The main conduction recovery sites of previous maze procedures were the perimitral (84.2%) and cavotricuspid isthmus (84.2%) areas, and recurrence mechanisms were macroreentry (63.2%) and focal/microreentry (26.3%) at scar border zones. Conclusions: Although hemodynamically corrected VAF was associated with advanced LA remodeling, the rhythm outcome did not significantly differ from that of NVAF after catheter ablation. (C) 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.subject | MITRAL-VALVE PROSTHESES | - |
dc.subject | RADIOFREQUENCY ABLATION | - |
dc.subject | FEASIBILITY | - |
dc.subject | SAFETY | - |
dc.subject | TRIAL | - |
dc.subject | MAZE | - |
dc.title | Clinical characteristics and rhythm outcome of catheter ablation of hemodynamically corrected valvular atrial fibrillation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Shim, Jaemin | - |
dc.contributor.affiliatedAuthor | Choi, Jong-Il | - |
dc.contributor.affiliatedAuthor | Kim, Young-Hoon | - |
dc.identifier.doi | 10.1016/j.jjcc.2018.10.014 | - |
dc.identifier.scopusid | 2-s2.0-85062451192 | - |
dc.identifier.wosid | 000474671400008 | - |
dc.identifier.bibliographicCitation | JOURNAL OF CARDIOLOGY, v.73, no.6, pp.488 - 496 | - |
dc.relation.isPartOf | JOURNAL OF CARDIOLOGY | - |
dc.citation.title | JOURNAL OF CARDIOLOGY | - |
dc.citation.volume | 73 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 488 | - |
dc.citation.endPage | 496 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Cardiovascular System & Cardiology | - |
dc.relation.journalWebOfScienceCategory | Cardiac & Cardiovascular Systems | - |
dc.subject.keywordPlus | MITRAL-VALVE PROSTHESES | - |
dc.subject.keywordPlus | RADIOFREQUENCY ABLATION | - |
dc.subject.keywordPlus | FEASIBILITY | - |
dc.subject.keywordPlus | SAFETY | - |
dc.subject.keywordPlus | TRIAL | - |
dc.subject.keywordPlus | MAZE | - |
dc.subject.keywordAuthor | Valvular atrial fibrillation | - |
dc.subject.keywordAuthor | Catheter ablation | - |
dc.subject.keywordAuthor | Maze operation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.