Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Application of artificial neural networks for optimized AHU discharge air temperature set-point and minimized cooling energy in VAV system

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Jong Man-
dc.contributor.authorHong, Sung Hyup-
dc.contributor.authorSeo, Byeong Mo-
dc.contributor.authorLee, Kwang Ho-
dc.date.accessioned2021-09-01T15:06:53Z-
dc.date.available2021-09-01T15:06:53Z-
dc.date.created2021-06-19-
dc.date.issued2019-05-05-
dc.identifier.issn1359-4311-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/65451-
dc.description.abstractChillers and boilers based air handling unit (AHU) system is one of the most widely used heating and cooling systems in office buildings in Korea. However, in most conventional forced-air systems, the guidelines for the AHU discharge air temperature (DAT) are not fully established and thus AHU DAT are constantly fixed to a particular set-point, regardless of dynamic changes of operating variables. In this circumstance, this study aimed at developing a control algorithm that can operate a conventional VAV system with optimal set-points for the AHU DAT. Three-story office building was modeled using co-simulation technique between EnergyPlus and Matlab via BCVTB (Building Controls Virtual Test Bed). In addition, artificial neural network (ANN) model, which was designed to predict the cooling energy consumption for the upcoming next time-step, was embedded into the control algorithm using neural network toolbox within Matlab. By comparing the predicted energy for the different set-points of the AHU DAT, the control algorithm can determine the most energy-effective AHU DAT set-point to minimize the cooling energy. The results showed that the prediction accuracy between simulated and predicted outcomes turned out to have a low coefficient of variation root mean square error (CvRMSE) value of approximately 24%. In addition, the predictive control algorithm was able to significantly reduce cooling energy consumption by approximately 10%, compared to a conventional control strategy of fixing AHU DAT to 14 degrees C. These findings suggest that the ANN model and the control algorithm showed energy saving potential for various types of forced air systems by taking dynamic operating conditions into account in each time-step.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectHANDLING UNITS-
dc.subjectCONTROL STRATEGIES-
dc.subjectOFFICE BUILDINGS-
dc.subjectEFFICIENCY-
dc.subjectSYNERGIZATION-
dc.titleApplication of artificial neural networks for optimized AHU discharge air temperature set-point and minimized cooling energy in VAV system-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Kwang Ho-
dc.identifier.doi10.1016/j.applthermaleng.2019.03.061-
dc.identifier.scopusid2-s2.0-85062848087-
dc.identifier.wosid000470194400066-
dc.identifier.bibliographicCitationAPPLIED THERMAL ENGINEERING, v.153, pp.726 - 738-
dc.relation.isPartOfAPPLIED THERMAL ENGINEERING-
dc.citation.titleAPPLIED THERMAL ENGINEERING-
dc.citation.volume153-
dc.citation.startPage726-
dc.citation.endPage738-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMechanics-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.relation.journalWebOfScienceCategoryMechanics-
dc.subject.keywordPlusHANDLING UNITS-
dc.subject.keywordPlusCONTROL STRATEGIES-
dc.subject.keywordPlusOFFICE BUILDINGS-
dc.subject.keywordPlusEFFICIENCY-
dc.subject.keywordPlusSYNERGIZATION-
dc.subject.keywordAuthorANN (Artificial Neural Network)-
dc.subject.keywordAuthorAHU (Air Handling Unit)-
dc.subject.keywordAuthorAHU Discharge Air Temperature (DAT)-
dc.subject.keywordAuthorEnergyPlus-
dc.subject.keywordAuthorMatlab-
dc.subject.keywordAuthorBCVTB (Building Controls Virtual Test Bed)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Architecture > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE