Quantitative analysis of radiation dosage and image quality between digital breast tomosynthesis (DBT) with two-dimensional synthetic mammography and full-field digital mammography (FFDM)
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Yoonmi | - |
dc.contributor.author | Woo, Ok-hee | - |
dc.contributor.author | Shin, Hye-sun | - |
dc.contributor.author | Cho, Kyu Ran | - |
dc.contributor.author | Seo, Bo Kyoung | - |
dc.contributor.author | Choi, Ga-Young | - |
dc.date.accessioned | 2021-09-01T15:52:03Z | - |
dc.date.available | 2021-09-01T15:52:03Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2019-05 | - |
dc.identifier.issn | 0899-7071 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/65923 | - |
dc.description.abstract | Purpose: Currently in diagnostic setting for breast cancer, FFDM and DBT are performed conjunctively. However, performing two imaging modalities may increase radiation exposure by double. Two-dimensional reconstructed images created from DBT with 2DSM, has a potential to replace conventional FFDM in concerning both radiation dosage and image quality. With increasing concerns for individual radiation exposure, studies analyzing radiation dosage in breast imaging modalities are needed. This study compared radiation dosage and image quality between DBT + 2DSM versus FFDM. Methods and materials: 374 patients (mean age 52 years) who underwent both DBT and FFDM were retrospectively reviewed. Radiation dosage data were obtained by radiation dosage scoring and monitoring program Radimetrics (Bayer HealthCare, Whippany, NJ). Entrance dose and mean glandular doses in each breast were obtained for both modalities. To compare image quality of DBT + 2DSM and FFDM, a 5-point scoring system for lesion clarity was assessed. The parameters of radiation dosage (entrance dose, mean glandular dose) and image quality (lesion clarity scoring) were compared. Results: For entrance dose, DBT had lower mean dosage (14.8 mGy) compared with FFDM (21.8 mGy, p-value < 0.0001). Mean glandular doses for both breasts were lower in DBT (Left 1.74, Right 2.1) compared with FFDM (Left 2.85, Right 2.74, p-value < 0.0001). Lesion clarity score was higher in DBT with 2DSM (mean score 4.03) compared with FFDM (3.82, p-value < 0.0001). Conclusion: DBT showed lower radiation entrance dose and mean glandular doses to both breasts compared with FFDM. DBT + 2DSM had better image quality than FFDM, suggesting that DBT with 2DSM has potential as an alternative to FFDM. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE INC | - |
dc.title | Quantitative analysis of radiation dosage and image quality between digital breast tomosynthesis (DBT) with two-dimensional synthetic mammography and full-field digital mammography (FFDM) | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Woo, Ok-hee | - |
dc.contributor.affiliatedAuthor | Cho, Kyu Ran | - |
dc.contributor.affiliatedAuthor | Seo, Bo Kyoung | - |
dc.identifier.doi | 10.1016/j.clinimag.2019.01.014 | - |
dc.identifier.scopusid | 2-s2.0-85060532720 | - |
dc.identifier.wosid | 000477692700004 | - |
dc.identifier.bibliographicCitation | CLINICAL IMAGING, v.55, pp.12 - 17 | - |
dc.relation.isPartOf | CLINICAL IMAGING | - |
dc.citation.title | CLINICAL IMAGING | - |
dc.citation.volume | 55 | - |
dc.citation.startPage | 12 | - |
dc.citation.endPage | 17 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordAuthor | Digital breast tomosynthesis | - |
dc.subject.keywordAuthor | Full-field digital mammography | - |
dc.subject.keywordAuthor | 2-Dimensional synthetic mammography | - |
dc.subject.keywordAuthor | Radimetrics | - |
dc.subject.keywordAuthor | Image quality | - |
dc.subject.keywordAuthor | Radiation dose | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.