Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Detection of Oil Release in Unsaturated Soil and Estimation of Oil Infiltration Rate Using Hydraulic Control System and Water Content Sensor

Authors
Lee, Sang-GilKim, Bong-JuChoi, Jae-WooLee, Soonjae
Issue Date
4월-2019
Publisher
SPRINGER INTERNATIONAL PUBLISHING AG
Keywords
Oil release detection; Volumetric water content; Hydraulic control system; Infiltration rate; Unsaturated soil; Underground storage tank
Citation
WATER AIR AND SOIL POLLUTION, v.230, no.4
Indexed
SCIE
SCOPUS
Journal Title
WATER AIR AND SOIL POLLUTION
Volume
230
Number
4
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/66430
DOI
10.1007/s11270-019-4147-4
ISSN
0049-6979
Abstract
Rapid detection of oil released from underground storage tanks and estimation of its flow rate allows for the prevention of further contamination or the limitation of the spread of contaminants. In this research, we developed a method for oil release detection by sensing volumetric water contents (VWC) in a hydraulic control system. Oil release detection tests were conducted at bench and pilot scales. In the bench-scale test, oil and water were released directly on top of the oil release detection system. In the pilot-scale test, the release detection system was installed in the soil and the oil was spilled on the soil surface. The new oil release monitoring system was capable of detecting the oil release using the VWC decrease (0.420.11m(3)/m(3)). The infiltration of water did not affect the value of VWC. Sequential injection or mixture of oil and water also showed a decrease in VWC (0.420.12m(3)/m(3)). The rate of VWC decrease was directly proportional (-0.003ml/min) to the rate of oil infiltration. A conceptual model was suggested to delineate the mechanism of oil release detection and to estimate the rate of oil infiltration. The detectability of the oil release in soil was also verified in the pilot-scale test (0.450.12m(3)/m(3)). The rate of oil infiltration could be estimated using the slope of the measured VWC. The amount of time for oil infiltration through the soil and dispersion during the migration should be considered to analyze the VWC curve properly. These results showed that the oil release detection system can be used to monitor oil release and to determine the rate of oil infiltration by installation in the soil near an underground storage tank.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Earth and Environmental Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE