Effects of collimator on imaging performance of Yttrium-90 Bremsstrahlung photons: Monte Carlo simulation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Minho | - |
dc.contributor.author | Bae, Jae Keon | - |
dc.contributor.author | Hong, Bong Hwan | - |
dc.contributor.author | Kim, Kyeong Min | - |
dc.contributor.author | Lee, Wonho | - |
dc.date.accessioned | 2021-09-01T16:55:45Z | - |
dc.date.available | 2021-09-01T16:55:45Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2019-04 | - |
dc.identifier.issn | 1738-5733 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/66446 | - |
dc.description.abstract | Yttrium-90 is a useful therapeutic radioisotope for tumor treatment because of its high-energy-emitting beta rays. However, it has been difficult to select appropriate collimators and main energy windows for Y-90 Bremsstrahlung imaging using gamma cameras because of the broad energy spectra of Y-90. We used a Monte Carlo simulation to investigate the effects of collimator selection and energy windows on Y-90 Bremsstrahlung imaging. We considered both MELP and HE collimators. Various phantoms were employed in the simulation to determine the main energy window using primary-to-scatter ratios (PSRs). Imaging performance was evaluated using spatial resolution indices, imaging counts, scatter fractions, and contrast-to-noise ratios. Collimator choice slightly affected energy spectrum shapes and improved PSRs. The HE collimator performed better than the MELP collimator on all imaging performance indices (except for imaging count). We observed minor differences in SR and SF values for the HE collimator among the five simulated energy windows. The combination of an HE collimator and improved-PSR energy window produced the best CNR value. In conclusion, appropriate collimator selection is an important component of Bremsstrahlung Y-90 photon imaging and main energy window determination. We found HE collimators to be more appropriate for improving the imaging performance of Bremsstrahlung Y-90 photons. (C) 2018 Korean Nuclear Society, Published by Elsevier Korea LLC. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN NUCLEAR SOC | - |
dc.subject | ENERGY WINDOW OPTIMIZATION | - |
dc.subject | PHANTOM | - |
dc.title | Effects of collimator on imaging performance of Yttrium-90 Bremsstrahlung photons: Monte Carlo simulation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Wonho | - |
dc.identifier.doi | 10.1016/j.net.2018.11.007 | - |
dc.identifier.scopusid | 2-s2.0-85057065079 | - |
dc.identifier.wosid | 000460093300024 | - |
dc.identifier.bibliographicCitation | NUCLEAR ENGINEERING AND TECHNOLOGY, v.51, no.2, pp.539 - 545 | - |
dc.relation.isPartOf | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
dc.citation.title | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
dc.citation.volume | 51 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 539 | - |
dc.citation.endPage | 545 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002438739 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.subject.keywordPlus | ENERGY WINDOW OPTIMIZATION | - |
dc.subject.keywordPlus | PHANTOM | - |
dc.subject.keywordAuthor | Yttrium-90 | - |
dc.subject.keywordAuthor | Bremsstrahlung imaging | - |
dc.subject.keywordAuthor | Collimator | - |
dc.subject.keywordAuthor | Energy window | - |
dc.subject.keywordAuthor | Gamma camera | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.