Self-Tuning Proportional-Type Performance Recovery Property Output Voltage-Tracking Algorithm for DC-DC Boost Converter
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Seok-Kyoon | - |
dc.contributor.author | Ahn, Choon Ki | - |
dc.date.accessioned | 2021-09-01T17:01:51Z | - |
dc.date.available | 2021-09-01T17:01:51Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2019-04 | - |
dc.identifier.issn | 0278-0046 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/66503 | - |
dc.description.abstract | This article exhibits an output voltage-tracking control algorithm incorporating a self-tuning algorithm and disturbance observers (DOBs) for dc-dc boost converters without tracking error integrators, considering model nonlinearities, parameter variations, and load uncertainties. The proposed algorithm is designed such that it forces the output voltage to track its target trajectory driven by a time-varying low-pass filter (LPF), despite model-plant mismatches. This paper makes two main contributions. First, it constructs the self-tuning algorithm by updating the closed-loop cut-off frequency in the time-varying LPF to improve the transient tracking performance. Second, it embeds first-order DOBs in the proportional-type nonlinear controller to achieve both performance recovery and the offset-free properties. The experimental verifications are carried out to illustrate the effectiveness of the closed-loop system driven by the proposed technique with a 3-kW prototype dc-dc boost converter; the 46% improvement of the tracking performance is observed, compared with the conventional feedback-linearization controller. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.subject | SLIDING-MODE CONTROL | - |
dc.subject | CONTROLLER | - |
dc.subject | DESIGN | - |
dc.subject | STABILIZATION | - |
dc.title | Self-Tuning Proportional-Type Performance Recovery Property Output Voltage-Tracking Algorithm for DC-DC Boost Converter | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Ahn, Choon Ki | - |
dc.identifier.doi | 10.1109/TIE.2018.2849982 | - |
dc.identifier.scopusid | 2-s2.0-85049310923 | - |
dc.identifier.wosid | 000452731500065 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, v.66, no.4, pp.3167 - 3175 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS | - |
dc.citation.title | IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS | - |
dc.citation.volume | 66 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 3167 | - |
dc.citation.endPage | 3175 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Automation & Control Systems | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Automation & Control Systems | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordPlus | SLIDING-MODE CONTROL | - |
dc.subject.keywordPlus | CONTROLLER | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordPlus | STABILIZATION | - |
dc.subject.keywordAuthor | Boost-type dc-dc converter | - |
dc.subject.keywordAuthor | disturbance observer (DOB) | - |
dc.subject.keywordAuthor | output voltage tracking | - |
dc.subject.keywordAuthor | self-tuning algorithm | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.