Transient analysis of attemperator enthalpy balance based on the commissioning data of a coal-fired steam power plant
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Uruno, Yumi | - |
dc.contributor.author | Choi, Geunwon | - |
dc.contributor.author | Sung, Minjun | - |
dc.contributor.author | Chung, Jaewon | - |
dc.contributor.author | Ki, Hyojun | - |
dc.contributor.author | Lee, Kihyun | - |
dc.date.accessioned | 2021-09-01T17:51:09Z | - |
dc.date.available | 2021-09-01T17:51:09Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2019-03-05 | - |
dc.identifier.issn | 1359-4311 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/67009 | - |
dc.description.abstract | In an attemperator, spray water is injected into superheated steam to control its temperature. Since the temperature measured by the thermowell installed at the attemperator outlet is used for the feedback control of the spray water, it is important that the spray water is completely evaporated before the thermowell. This ensures that the thermowell measures the temperature of desuperheated steam. In this study, measurements from the commissioning test of a coal-fired steam power plant were analyzed using transient analyses. These analyses compensated for delayed temperature measurement at thermowells with large heat capacities and the temperature change of spray water extracted far from the attemperator. By using these results for the enthalpy balance in the attemperator, the spray water flow could be calculated accurately enough to verify whether the spray-injected steam was completely desuperheated before the outlet thermowell or not, even during operations with changing the generator load. Temperature readings from thermowells depend on the subcritical and supercritical conditions and the validity of the various simplifications used in the transient analysis were discussed. According to the transient analysis of the commissioning data, the thermowell distance in one of the attemperators could be judged as being too short to ensure complete desuperheating of the spray-injected steam, and thus, this should be considered in the control logic. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | PERGAMON-ELSEVIER SCIENCE LTD | - |
dc.subject | TEMPERATURE | - |
dc.subject | SIMULATION | - |
dc.subject | DYNAMICS | - |
dc.subject | MODEL | - |
dc.subject | HEAT | - |
dc.title | Transient analysis of attemperator enthalpy balance based on the commissioning data of a coal-fired steam power plant | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Chung, Jaewon | - |
dc.identifier.doi | 10.1016/j.applthermaleng.2019.01.047 | - |
dc.identifier.scopusid | 2-s2.0-85060739144 | - |
dc.identifier.wosid | 000462418200101 | - |
dc.identifier.bibliographicCitation | APPLIED THERMAL ENGINEERING, v.150, pp.1141 - 1158 | - |
dc.relation.isPartOf | APPLIED THERMAL ENGINEERING | - |
dc.citation.title | APPLIED THERMAL ENGINEERING | - |
dc.citation.volume | 150 | - |
dc.citation.startPage | 1141 | - |
dc.citation.endPage | 1158 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Thermodynamics | - |
dc.relation.journalResearchArea | Energy & Fuels | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Mechanics | - |
dc.relation.journalWebOfScienceCategory | Thermodynamics | - |
dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
dc.relation.journalWebOfScienceCategory | Mechanics | - |
dc.subject.keywordPlus | TEMPERATURE | - |
dc.subject.keywordPlus | SIMULATION | - |
dc.subject.keywordPlus | DYNAMICS | - |
dc.subject.keywordPlus | MODEL | - |
dc.subject.keywordPlus | HEAT | - |
dc.subject.keywordAuthor | Power plant | - |
dc.subject.keywordAuthor | Attemperator | - |
dc.subject.keywordAuthor | Spray | - |
dc.subject.keywordAuthor | Thermowell | - |
dc.subject.keywordAuthor | Transient analysis | - |
dc.subject.keywordAuthor | Enthalpy balance | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.