Simulation Studies for Noninvasive Optical Measurements of Blood-Scattering Changes in a Skin Model with a large Blood Vessel
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Phillips, Zephaniah, V | - |
dc.contributor.author | Paik, Seung-Ho | - |
dc.contributor.author | Nam, Jungyong | - |
dc.contributor.author | Chang, Ki Young | - |
dc.contributor.author | Jung, Young-Tin | - |
dc.contributor.author | Choi, Youngwoon | - |
dc.contributor.author | Lee, Joonhyung | - |
dc.contributor.author | Kim, Beop Min | - |
dc.date.accessioned | 2021-09-01T18:28:51Z | - |
dc.date.available | 2021-09-01T18:28:51Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2019-02-25 | - |
dc.identifier.issn | 2508-7266 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/67286 | - |
dc.description.abstract | Monte Carlo simulations were performed for a three-dimensional tissue model with and without an embedded large vessel, to understand how varying vessel geometry affects surface light distribution. Vessel radius was varied from 1 to 5 mm, and vessel depth from 2 to 10 mm. A larger difference in surface fluence rate was observed when the vessel's radius increased. For vessel depth, the largest difference was seen at a depth of approximately 4 mm, corresponding to human wrist region. When the vessel was placed at depths greater than 8 mm, very little difference was observed. We also tested the feasibility of using two source-detector pairs, comprising two detectors distinctly spaced from a common source, to noninvasively measure blood-scattering changes in a large vessel. High sensitivity to blood-scattering changes was achieved by placing the near detector closer to the source and moving the far detector away from the source. However, at longer distances, increasing noise levels limited the sensitivity of the two-detector approach. Our results indicate that the approach using two source-detector pairs may have potential for quantitative measurement of scattering changes in the blood while targeting large vessels near the human wrist region. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | OPTICAL SOC KOREA | - |
dc.subject | MONTE-CARLO | - |
dc.subject | LIGHT DISTRIBUTIONS | - |
dc.subject | PHOTON MIGRATION | - |
dc.subject | TISSUES | - |
dc.subject | WAVELENGTHS | - |
dc.subject | DIAMETER | - |
dc.subject | ARTERY | - |
dc.title | Simulation Studies for Noninvasive Optical Measurements of Blood-Scattering Changes in a Skin Model with a large Blood Vessel | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Choi, Youngwoon | - |
dc.contributor.affiliatedAuthor | Kim, Beop Min | - |
dc.identifier.doi | 10.3807/COPP.2019.3.1.046 | - |
dc.identifier.scopusid | 2-s2.0-85069481218 | - |
dc.identifier.wosid | 000459856700008 | - |
dc.identifier.bibliographicCitation | CURRENT OPTICS AND PHOTONICS, v.3, no.1, pp.46 - 53 | - |
dc.relation.isPartOf | CURRENT OPTICS AND PHOTONICS | - |
dc.citation.title | CURRENT OPTICS AND PHOTONICS | - |
dc.citation.volume | 3 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 46 | - |
dc.citation.endPage | 53 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002439430 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Optics | - |
dc.relation.journalWebOfScienceCategory | Optics | - |
dc.subject.keywordPlus | MONTE-CARLO | - |
dc.subject.keywordPlus | LIGHT DISTRIBUTIONS | - |
dc.subject.keywordPlus | PHOTON MIGRATION | - |
dc.subject.keywordPlus | TISSUES | - |
dc.subject.keywordPlus | WAVELENGTHS | - |
dc.subject.keywordPlus | DIAMETER | - |
dc.subject.keywordPlus | ARTERY | - |
dc.subject.keywordAuthor | Monte Carlo | - |
dc.subject.keywordAuthor | Blood vessel | - |
dc.subject.keywordAuthor | Scattering | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.