Comparison of Three Different Tonometers in Eyes with Angle Closure
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Tae-Eun | - |
dc.contributor.author | Yoo, Chungkwon | - |
dc.contributor.author | Kim, Yong Yeon | - |
dc.date.accessioned | 2021-09-01T20:12:43Z | - |
dc.date.available | 2021-09-01T20:12:43Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2019-02 | - |
dc.identifier.issn | 1040-5488 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/67859 | - |
dc.description.abstract | Supplemental digital content is available in the text. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | LIPPINCOTT WILLIAMS & WILKINS | - |
dc.subject | INTRAOCULAR-PRESSURE MEASUREMENTS | - |
dc.subject | GOLDMANN APPLANATION TONOMETER | - |
dc.subject | LATERAL DECUBITUS POSITION | - |
dc.subject | PRO REBOUND TONOMETER | - |
dc.subject | TONO-PEN | - |
dc.subject | GLAUCOMA PROGRESSION | - |
dc.subject | CLINICAL-EVALUATION | - |
dc.subject | SELF-TONOMETRY | - |
dc.subject | IOP | - |
dc.subject | ACCURACY | - |
dc.title | Comparison of Three Different Tonometers in Eyes with Angle Closure | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yoo, Chungkwon | - |
dc.contributor.affiliatedAuthor | Kim, Yong Yeon | - |
dc.identifier.doi | 10.1097/OPX.0000000000001325 | - |
dc.identifier.scopusid | 2-s2.0-85060926083 | - |
dc.identifier.wosid | 000457561200008 | - |
dc.identifier.bibliographicCitation | OPTOMETRY AND VISION SCIENCE, v.96, no.2, pp.124 - 129 | - |
dc.relation.isPartOf | OPTOMETRY AND VISION SCIENCE | - |
dc.citation.title | OPTOMETRY AND VISION SCIENCE | - |
dc.citation.volume | 96 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 124 | - |
dc.citation.endPage | 129 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Ophthalmology | - |
dc.relation.journalWebOfScienceCategory | Ophthalmology | - |
dc.subject.keywordPlus | INTRAOCULAR-PRESSURE MEASUREMENTS | - |
dc.subject.keywordPlus | GOLDMANN APPLANATION TONOMETER | - |
dc.subject.keywordPlus | LATERAL DECUBITUS POSITION | - |
dc.subject.keywordPlus | PRO REBOUND TONOMETER | - |
dc.subject.keywordPlus | TONO-PEN | - |
dc.subject.keywordPlus | GLAUCOMA PROGRESSION | - |
dc.subject.keywordPlus | CLINICAL-EVALUATION | - |
dc.subject.keywordPlus | SELF-TONOMETRY | - |
dc.subject.keywordPlus | IOP | - |
dc.subject.keywordPlus | ACCURACY | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.