Optimal design of generators for H2O/LiBr absorption chiller with multi-heat sources
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Su Kyoung | - |
dc.contributor.author | Lee, Jae Won | - |
dc.contributor.author | Lee, Hoseong | - |
dc.contributor.author | Chung, Jin Taek | - |
dc.contributor.author | Kang, Yong Tae | - |
dc.date.accessioned | 2021-09-01T21:31:00Z | - |
dc.date.available | 2021-09-01T21:31:00Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2019-01-15 | - |
dc.identifier.issn | 0360-5442 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/68295 | - |
dc.description.abstract | In this paper, the various optimized generators for H2O/LiBr absorption chiller with multi-heat sources are discussed. While the previous optimization has been mainly conducted for a single element, the integrated generation system including high/low temperature generator and waste heat recovery generator is optimized in this paper. A practical modeling method is proposed for the high/low temperature generator and it has been verified by comparing with experimental results. Meta-models for the volume and the generation rate are built with kriging method, and the generators are optimized by multi-objective optimization technique using the meta-models. The total volume is minimized and the total generation rate is maximized according to five design variables of the generators. It is found that from the optimization process the total volume is decreased by 59.06% and the total generation rate is increased by 31.46% compared to the baseline point. It is concluded that the contribution of the waste heat recovery generator and the high temperature generator are dominant for the total volume reduction and the total generation rate improvement, respectively. Moreover, the effects of the key variables on the performance of each generator are analyzed according to the optimization of the integrated generation system. (C) 2018 Elsevier Ltd. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | PERGAMON-ELSEVIER SCIENCE LTD | - |
dc.subject | FALLING-FILM EVAPORATION | - |
dc.subject | AMMONIA SPRAY EVAPORATOR | - |
dc.subject | PLAIN-TUBE BUNDLE | - |
dc.subject | ENHANCED TUBES | - |
dc.subject | MULTIOBJECTIVE OPTIMIZATION | - |
dc.subject | NUMERICAL-SIMULATION | - |
dc.subject | TRANSFER PERFORMANCE | - |
dc.subject | HORIZONTAL TUBES | - |
dc.subject | MASS-TRANSFER | - |
dc.subject | PART I | - |
dc.title | Optimal design of generators for H2O/LiBr absorption chiller with multi-heat sources | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Hoseong | - |
dc.contributor.affiliatedAuthor | Chung, Jin Taek | - |
dc.contributor.affiliatedAuthor | Kang, Yong Tae | - |
dc.identifier.doi | 10.1016/j.energy.2018.10.185 | - |
dc.identifier.scopusid | 2-s2.0-85057146988 | - |
dc.identifier.wosid | 000456351800005 | - |
dc.identifier.bibliographicCitation | ENERGY, v.167, pp.47 - 59 | - |
dc.relation.isPartOf | ENERGY | - |
dc.citation.title | ENERGY | - |
dc.citation.volume | 167 | - |
dc.citation.startPage | 47 | - |
dc.citation.endPage | 59 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Thermodynamics | - |
dc.relation.journalResearchArea | Energy & Fuels | - |
dc.relation.journalWebOfScienceCategory | Thermodynamics | - |
dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
dc.subject.keywordPlus | FALLING-FILM EVAPORATION | - |
dc.subject.keywordPlus | AMMONIA SPRAY EVAPORATOR | - |
dc.subject.keywordPlus | PLAIN-TUBE BUNDLE | - |
dc.subject.keywordPlus | ENHANCED TUBES | - |
dc.subject.keywordPlus | MULTIOBJECTIVE OPTIMIZATION | - |
dc.subject.keywordPlus | NUMERICAL-SIMULATION | - |
dc.subject.keywordPlus | TRANSFER PERFORMANCE | - |
dc.subject.keywordPlus | HORIZONTAL TUBES | - |
dc.subject.keywordPlus | MASS-TRANSFER | - |
dc.subject.keywordPlus | PART I | - |
dc.subject.keywordAuthor | Absorption chiller | - |
dc.subject.keywordAuthor | Generator | - |
dc.subject.keywordAuthor | H2O/LiBr | - |
dc.subject.keywordAuthor | Multi-heat sources | - |
dc.subject.keywordAuthor | Optimization | - |
dc.subject.keywordAuthor | Tri-generation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.