Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Dorsal transosseous reduction and locking plate fixation for articular depressed middle phalangeal base fracture

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Ji Hun-
dc.contributor.authorPark, Geun Woo-
dc.contributor.authorChoi, In Cheul-
dc.contributor.authorKwon, Young Woo-
dc.contributor.authorPark, Jong Woong-
dc.date.accessioned2021-09-01T22:34:16Z-
dc.date.available2021-09-01T22:34:16Z-
dc.date.created2021-06-19-
dc.date.issued2019-01-
dc.identifier.issn0936-8051-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/68828-
dc.description.abstractPurposeAn articular depressed fragment at the base of the middle phalanx can be an obstacle to congruent reduction and stable fixation. This study assessed the outcomes of a transosseous reduction technique combined with locking plate fixation for the treatment of articular depressed middle phalangeal base fracture.MethodsBetween 2015 and 2017, seven patients (eight fingers) with intraarticular comminuted middle phalangeal base fracture were included in this study. Mean follow-up was 19 months (range 12-30 months). All patients showed depression of the articular fragment on sagittal computed tomography (CT) scan and were treated with a transosseous reduction technique and dorsal locking plate fixation. Radiographic evaluation was performed to ensure restoration of a concentric articular surface postoperatively. Total active range of motion (TAM) of the finger, grip strength, and the quick Disabilities of the Arm, Shoulder and Hand (quick DASH) score were evaluated at the last follow-up. Complications were also assessed.ResultsAll fractures obtained bony union with a concentric joint. There was no significant loss of reduction during the follow-up period. The mean active proximal interphalangeal (PIP) joint and distal interphalangeal joint motion arcs at follow-up were 89 degrees and 61 degrees, respectively. Mean TAM of the affected finger and mean grip strength were 94% (range 80-100%) and 94% (range 86-100%) of the contralateral side, respectively. Mean quick DASH score was 2.3 (range 0-9.1). All patients returned to work. No surgery-related complications occurred.ConclusionsThis technique provides satisfactory restoration of articular congruence and enables the early joint mobilization of articular depression-type fractures of the base of the middle phalanx.Type of study/level of evidenceTherapeutic, level IV.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherSPRINGER-
dc.subjectPROXIMAL INTERPHALANGEAL JOINT-
dc.subjectDYNAMIC EXTERNAL FIXATION-
dc.subjectINTERNAL-FIXATION-
dc.subjectSCREW FIXATION-
dc.subjectACTIVE MOTION-
dc.subjectPINS-
dc.subjectDISLOCATIONS-
dc.subjectTRACTION-
dc.subjectFINGER-
dc.subjectSYSTEM-
dc.titleDorsal transosseous reduction and locking plate fixation for articular depressed middle phalangeal base fracture-
dc.typeArticle-
dc.contributor.affiliatedAuthorPark, Jong Woong-
dc.identifier.doi10.1007/s00402-018-3074-y-
dc.identifier.scopusid2-s2.0-85057194997-
dc.identifier.wosid000456950700018-
dc.identifier.bibliographicCitationARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, v.139, no.1, pp.141 - 145-
dc.relation.isPartOfARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY-
dc.citation.titleARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY-
dc.citation.volume139-
dc.citation.number1-
dc.citation.startPage141-
dc.citation.endPage145-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOrthopedics-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryOrthopedics-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusPROXIMAL INTERPHALANGEAL JOINT-
dc.subject.keywordPlusDYNAMIC EXTERNAL FIXATION-
dc.subject.keywordPlusINTERNAL-FIXATION-
dc.subject.keywordPlusSCREW FIXATION-
dc.subject.keywordPlusACTIVE MOTION-
dc.subject.keywordPlusPINS-
dc.subject.keywordPlusDISLOCATIONS-
dc.subject.keywordPlusTRACTION-
dc.subject.keywordPlusFINGER-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordAuthorArticular depression-
dc.subject.keywordAuthorIntraarticular fracture-
dc.subject.keywordAuthorMiddle phalanx-
dc.subject.keywordAuthorPlate fixation-
dc.subject.keywordAuthorTransosseous reduction-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Altmetrics

Total Views & Downloads

BROWSE