Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

IEC 규정 노출지수를 활용한 디지털 방사선 영상시스템에서의 영상 수용체간 특성평가 (Ⅰ)

Full metadata record
DC Field Value Language
dc.contributor.author박혜민-
dc.contributor.author윤용수-
dc.contributor.author노영훈-
dc.contributor.author김성준-
dc.contributor.author나찬영-
dc.contributor.author한태호-
dc.contributor.author김정수-
dc.contributor.author정회원-
dc.contributor.author김정민-
dc.date.accessioned2021-09-01T23:39:54Z-
dc.date.available2021-09-01T23:39:54Z-
dc.date.created2021-06-17-
dc.date.issued2019-
dc.identifier.issn2288-3509-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/69572-
dc.description.abstractThe International Electrotechnical Commission (IEC) has regulated the definition and requirements of the exposure index (EI). In this study, we calculated the EI of several image receptors in digital radiography system of two different manufacturers according to the method as per IEC, and evaluated the relationship with incident air kerma. To calculate t he E I, w e obtained the characteristics curve of e ach i mage receptor b y increasing t he i ncident air kerma at R QA 3, 5, 7 and 9, respectively. As a result, there was no significant difference in the EI values between different image receptors of the same manufacturer, but EI values of different manufacturer was different despite the same air kerma was incident. Therefore, understanding the characteristics of the digital radiography systems is important in order to use EI as a tool for measuring and managing the radiation dose.-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한방사선과학회-
dc.titleIEC 규정 노출지수를 활용한 디지털 방사선 영상시스템에서의 영상 수용체간 특성평가 (Ⅰ)-
dc.title.alternativeEvaluation of Image Receptor Characteristics in Computed Radiography System Using Exposure Index in International Electrotechnical Commission (Ⅰ)-
dc.typeArticle-
dc.contributor.affiliatedAuthor김정민-
dc.identifier.bibliographicCitation방사선기술과학, v.42, no.4, pp.291 - 299-
dc.relation.isPartOf방사선기술과학-
dc.citation.title방사선기술과학-
dc.citation.volume42-
dc.citation.number4-
dc.citation.startPage291-
dc.citation.endPage299-
dc.type.rimsART-
dc.identifier.kciidART002497975-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorCharacteristics Curve-
dc.subject.keywordAuthorComputed Radiography System-
dc.subject.keywordAuthorDigital Radiography System-
dc.subject.keywordAuthorExposure Index-
dc.subject.keywordAuthorImage Receptor-
dc.subject.keywordAuthor특성곡선-
dc.subject.keywordAuthor컴퓨터 방사선 영상시스템-
dc.subject.keywordAuthor디지털 방사선 영상시스템-
dc.subject.keywordAuthor노출지수-
dc.subject.keywordAuthor영상 수용체-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE