Studies on sub-millimeter LYSO:Ce, Ce:GAGG, and a new Ce:GFAG block detector for PET using digital silicon photomultiplier
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ullah, Muhammad Nasir | - |
dc.contributor.author | Pratiwi, Eva | - |
dc.contributor.author | Park, Jin Ho | - |
dc.contributor.author | Yamamoto, Seiichi | - |
dc.contributor.author | Kamada, Kei | - |
dc.contributor.author | Yoshikawa, Akira | - |
dc.contributor.author | Yeom, Jung-Yeol | - |
dc.date.accessioned | 2021-09-02T02:11:05Z | - |
dc.date.available | 2021-09-02T02:11:05Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2018-12-11 | - |
dc.identifier.issn | 0168-9002 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/71215 | - |
dc.description.abstract | The spatial, timing, and energy resolutions of a detector affect the image quality of a positron emission tomography (PET) system. These parameters are in turn dependent on various factors, such as the choice of scintillator, photodetectors, reflector material, and surface treatment (rough or polished) of the scintillators. In this study, we investigated the performances of sub-millimeter scintillator array, LYSO:Ce (polished and rough surfaces with BaSO4 reflector or enhanced specular reflector (ESR)), a gadolinium aluminum gallium garnet (Ce:GAGG, rough surface with BaSO4 reflector), and a new gadolinium fine aluminum gallate (Ce:GFAG, rough surface with BaSO4 reflector) detectors. The outer dimension of each scintillator block was similar to 12 x 12 mm with a 12 x 12 matrix of 0.9 x0.9x 6 mm(3) crystal elements. These blocks were optically coupled to a digital silicon photomultiplier (dSiPM, DPC-3200-22-44) with a 1 mm thick optical guide. Experiments were conducted at a sensor temperature of similar to 15 degrees C, and a two-dimensional position histogram for Na-22 gamma photons showed that all pixels were clearly resolved for all block detectors (peak-to-valley ratios ranging from 5.3 to 11.1). The average energy resolutions for the LYSO (ESR, rough), LYSO (ESR, polished), LYSO (BaSO4, rough), LYSO (BaSO4, polished), GAGG (BaSO4, rough), and GFAG (BaSO4, rough) arrays were measured as 11.3%, 10.2%, 18.7%, 10.3%, 10.0%, and 13.2% full width at half maximum (FWHM), respectively. The coincidence resolving times (with 3 x 3 x 5 mm(3) LYSO crystal as reference) for the LYSO (ESR, rough), LYSO (ESR, polished), LYSO (BaSO4, rough), LYSO (BaSO4, polished), GAGG (BaSO4, rough), and GFAG (BaSO4, rough) arrays were 209 ps, 222 ps, 197 ps, 230 ps, 321 ps, and 276 ps, respectively. In conclusion, the new GFAG scintillator may be a promising candidate for future high-resolution time-of-flight (ToF) PET systems, considering the tradeoff between its performance and potential to be grown at a lower cost. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.subject | RESOLUTION | - |
dc.subject | SCINTILLATORS | - |
dc.subject | PERFORMANCE | - |
dc.subject | READOUT | - |
dc.subject | SIPM | - |
dc.subject | CE | - |
dc.title | Studies on sub-millimeter LYSO:Ce, Ce:GAGG, and a new Ce:GFAG block detector for PET using digital silicon photomultiplier | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yeom, Jung-Yeol | - |
dc.identifier.doi | 10.1016/j.nima.2018.09.029 | - |
dc.identifier.scopusid | 2-s2.0-85054903032 | - |
dc.identifier.wosid | 000450880200017 | - |
dc.identifier.bibliographicCitation | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.911, pp.115 - 122 | - |
dc.relation.isPartOf | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | - |
dc.citation.title | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | - |
dc.citation.volume | 911 | - |
dc.citation.startPage | 115 | - |
dc.citation.endPage | 122 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Physics, Nuclear | - |
dc.relation.journalWebOfScienceCategory | Physics, Particles & Fields | - |
dc.subject.keywordPlus | RESOLUTION | - |
dc.subject.keywordPlus | SCINTILLATORS | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | READOUT | - |
dc.subject.keywordPlus | SIPM | - |
dc.subject.keywordPlus | CE | - |
dc.subject.keywordAuthor | Scintillation detector | - |
dc.subject.keywordAuthor | Digital silicon photomultiplier | - |
dc.subject.keywordAuthor | Time-of-flight positron emission tomography | - |
dc.subject.keywordAuthor | Timing resolution | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.