Beam position monitor for superconducting post-linac in RAON
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kwon, J. W. | - |
dc.contributor.author | Woo, H. J. | - |
dc.contributor.author | Kim, G. D. | - |
dc.contributor.author | Chung, Y. S. | - |
dc.contributor.author | Kim, E. -S. | - |
dc.date.accessioned | 2021-09-02T03:33:54Z | - |
dc.date.available | 2021-09-02T03:33:54Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2018-11-11 | - |
dc.identifier.issn | 0168-9002 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/71859 | - |
dc.description.abstract | The Rare-isotope Accelerator complex for ON-line experiments (RAON) is an accelerator for heavy ions, such as uranium and oxygen. To correct the beam trajectory in the post-linac with low- beta, we developed a beam position monitor. In the post-linac, the beam is accelerated from 0.5 MeV/u to 18.5 MeV/u, and each bunch has an electric charge of less than 10 pC. To achieve higher signal strength and better linearity, we investigated stripline- and button-type beam position monitor (BPM) and designed the BPMs with CST Particle Studio. We have fabricated a button-type BPM. We tested 10 BPMs by using a wire test stand to achieve the characterization of each BPM, including the calibration factor with single-pass H electronics of I-Tech. The developed wire test stand has a stretched wire and is movable in the 2D plane with servomotors. In this paper, we present the results of the design, fabrication, and off-line test of a button-type BPM for a low-beta, heavy-ion beam. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.title | Beam position monitor for superconducting post-linac in RAON | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, E. -S. | - |
dc.identifier.doi | 10.1016/j.nima.2018.08.046 | - |
dc.identifier.scopusid | 2-s2.0-85052463052 | - |
dc.identifier.wosid | 000446864600017 | - |
dc.identifier.bibliographicCitation | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.908, pp.136 - 142 | - |
dc.relation.isPartOf | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | - |
dc.citation.title | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | - |
dc.citation.volume | 908 | - |
dc.citation.startPage | 136 | - |
dc.citation.endPage | 142 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Physics, Nuclear | - |
dc.relation.journalWebOfScienceCategory | Physics, Particles & Fields | - |
dc.subject.keywordAuthor | Linear accelerator | - |
dc.subject.keywordAuthor | Beam diagnostics | - |
dc.subject.keywordAuthor | Beam position monitor | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.