Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of quantitative imaging parameters using cardiovascular magnetic resonance between cardiac amyloidosis and hypertrophic cardiomyopathy: inversion time scout versus T1 mapping

Full metadata record
DC Field Value Language
dc.contributor.authorNam, Bo Da-
dc.contributor.authorKim, Sung Mok-
dc.contributor.authorJung, Hye Na-
dc.contributor.authorKim, Yiseul-
dc.contributor.authorChoe, Yeon Hyeon-
dc.date.accessioned2021-09-02T04:17:07Z-
dc.date.available2021-09-02T04:17:07Z-
dc.date.created2021-06-19-
dc.date.issued2018-11-
dc.identifier.issn1569-5794-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/72005-
dc.description.abstractTo compare inversion time (TI) parameters, native T1, and extracellular volume (ECV) on cardiac magnetic resonance (CMR) imaging between patients with cardiac amyloidosis (CA) or hypertrophic cardiomyopathy (HCMP). Forty six patients with biopsy-confirmed CA and 30 patients with HCMP who underwent CMR were included. T1 and TI values were measured in the septum and cavity of the left ventricle on T1 mapping and TI scout images. TI values were selected at nulling point for each myocardium and blood pool. Native T1, ECV, and TI interval values were significantly different between the CA (1170.5 +/- 86.4ms, 56.7 +/- 12.2, -11.5 +/- 28.4ms) and HCMP (1059.5 +/- 63.4ms, 28.5 +/- 5.8, 66.2 +/- 25.4ms) (all p<0.001). The diagnostic performance of the TI interval (area under the ROC curve, 0.975) was not inferior to that of the ECV (0.980, p=0.776), and it was superior to that of the native T1 (0.845, p=0.004). The diagnostic performance of TI interval was comparable to that of ECV for differential diagnosis between CA and HCMP. TI interval showed the feasibility as quantitative CMR parameter when T1 mapping images are not available.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherSPRINGER-
dc.subjectENDOMYOCARDIAL BIOPSY-
dc.subjectQUANTIFICATION-
dc.subjectDISEASE-
dc.subjectEXPANSION-
dc.subjectVOLUME-
dc.titleComparison of quantitative imaging parameters using cardiovascular magnetic resonance between cardiac amyloidosis and hypertrophic cardiomyopathy: inversion time scout versus T1 mapping-
dc.typeArticle-
dc.contributor.affiliatedAuthorJung, Hye Na-
dc.identifier.doi10.1007/s10554-018-1385-2-
dc.identifier.scopusid2-s2.0-85047828954-
dc.identifier.wosid000447415600011-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, v.34, no.11, pp.1769 - 1777-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING-
dc.citation.titleINTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING-
dc.citation.volume34-
dc.citation.number11-
dc.citation.startPage1769-
dc.citation.endPage1777-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusENDOMYOCARDIAL BIOPSY-
dc.subject.keywordPlusQUANTIFICATION-
dc.subject.keywordPlusDISEASE-
dc.subject.keywordPlusEXPANSION-
dc.subject.keywordPlusVOLUME-
dc.subject.keywordAuthorAmyloidosis-
dc.subject.keywordAuthorCardiovascular magnetic resonance-
dc.subject.keywordAuthorExtracellular volume-
dc.subject.keywordAuthorHypertrophic cardiomyopathy-
dc.subject.keywordAuthorInversion time-