Toward a novel dosimetry system using acrylic disk radiation sensor for proton pencil beam scanning
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, Shinhaeng | - |
dc.contributor.author | Lee, Nuri | - |
dc.contributor.author | Song, Sanghyeon | - |
dc.contributor.author | Son, Jaeman | - |
dc.contributor.author | Kim, Haksoo | - |
dc.contributor.author | Jeong, Jong Hwi | - |
dc.contributor.author | Lee, Se Byeong | - |
dc.contributor.author | Lim, Youngkyung | - |
dc.contributor.author | Moon, Sunyoung | - |
dc.contributor.author | Yoon, Myonggeun | - |
dc.contributor.author | Shin, Dongho | - |
dc.date.accessioned | 2021-09-02T04:21:16Z | - |
dc.date.available | 2021-09-02T04:21:16Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2018-11 | - |
dc.identifier.issn | 0094-2405 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/72038 | - |
dc.description.abstract | Purpose Methods Fabricate an acrylic disk radiation sensor (ADRS) and characterize the photoluminescence signal generated from the optical device as basis for the development and evaluation of a new dosimetry system for pencil beam proton therapy. Based on the characteristics of the proposed optical dosimetry sensor, we established the relation between the photoluminescence output and the applied dose using an ionization chamber. Then, we obtained the relative integral depth dose profiles using the photoluminescence signal generated by pencil beam irradiation at energies of 99.9 and 162.1 MeV, and compared the results with the curve measured using a Bragg peak ionization chamber. Results Conclusions The relation between the photoluminescence output and applied dose was linear. In addition, the ADRS was dose independent for beam currents up to 6 Gy/min, and the calibration factor for energy was close to 1. Hence, the energy dependence on the optical device can be disregarded. The integral depth dose profiles obtained for the ADRS suitable agreed with the curve measured in the Bragg peak ionization chamber without requiring correction. These results suggest that the ADRS is suitable for dosimetry measurements in pencil beam scanning, and it will be employed as a low-cost and versatile dosimetry sensor in upcoming developments. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | CERENKOV RADIATION | - |
dc.subject | THERAPY DOSIMETRY | - |
dc.subject | DETECTORS | - |
dc.title | Toward a novel dosimetry system using acrylic disk radiation sensor for proton pencil beam scanning | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yoon, Myonggeun | - |
dc.identifier.doi | 10.1002/mp.13149 | - |
dc.identifier.scopusid | 2-s2.0-85053891753 | - |
dc.identifier.wosid | 000449995900057 | - |
dc.identifier.bibliographicCitation | MEDICAL PHYSICS, v.45, no.11, pp.5277 - 5282 | - |
dc.relation.isPartOf | MEDICAL PHYSICS | - |
dc.citation.title | MEDICAL PHYSICS | - |
dc.citation.volume | 45 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 5277 | - |
dc.citation.endPage | 5282 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | CERENKOV RADIATION | - |
dc.subject.keywordPlus | THERAPY DOSIMETRY | - |
dc.subject.keywordPlus | DETECTORS | - |
dc.subject.keywordAuthor | acrylic disk | - |
dc.subject.keywordAuthor | Bragg ionization chamber | - |
dc.subject.keywordAuthor | integral depth-dose | - |
dc.subject.keywordAuthor | pencil beam scanning | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.