Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fluorescence-based immunosensor using three-dimensional CNT network structure for sensitive and reproducible detection of oral squamous cell carcinoma biomarker

Full metadata record
DC Field Value Language
dc.contributor.authorSong, Chung Kil-
dc.contributor.authorOh, Eunkyul-
dc.contributor.authorKang, Min Sung-
dc.contributor.authorShin, Bum Seok-
dc.contributor.authorHan, Soo Young-
dc.contributor.authorJung, Mingi-
dc.contributor.authorLee, Eui Seok-
dc.contributor.authorYoon, Soo-Young-
dc.contributor.authorSung, Myung Mo-
dc.contributor.authorNg, Wei Beng-
dc.contributor.authorCho, Nam-Joon-
dc.contributor.authorLee, Haiwon-
dc.date.accessioned2021-09-02T05:07:59Z-
dc.date.available2021-09-02T05:07:59Z-
dc.date.created2021-06-19-
dc.date.issued2018-10-16-
dc.identifier.issn0003-2670-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/72471-
dc.description.abstractA hierarchical three-dimensional network of carbon nanotubes on Si pillar substrate (3DN-CNTs) was developed for the accurate detection of oral squamous cell carcinoma (OSCC) in clinical saliva samples. The 3DN-CNTs were uniformly coated with a layer of aluminum oxides to enhance structural stability during biomarker detection. Cytokeratin-19 antigen (Cyfra 21-1) was utilized as a model biomarker of OSCC for fluorescence-based immunosensor using 3DN-CNTs (3DN-CNTs sensor). The 3DN-CNTs sensor enhances the sensitivity of Cyfra 21-1 detection by increasing the density of immobilized antibody through high surface area of 3DN-CNTs and enhancing the accessibility of biomolecules through the ordered pathway of hierarchical structure. The reliable detection limit for sensing of Cyfra 21-1 was estimated as in the level of 0.5 ng/mL and the quantitative estimation of Cyfra 21-1 was analyzed by 4parameter logistic (4-PL) model for curve-fitting analysis. Clinical applicability of 3DN-CNTs sensor was evaluated through correlation with the commercially available electrochemiluminescence (ECL) detection system in the hospital. The assay results of the two systems for clinical saliva samples showed a good linear correlation. The 3DN-CNTs sensor offers great potential for accurate diagnosis of OSCC using Cyfra 21-1 biomarker in clinical fluids. (C) 2018 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectTUMOR-MARKERS-
dc.subjectCANCER BIOMARKERS-
dc.subjectSURFACE-DENSITY-
dc.subjectTHIN-LAYERS-
dc.subjectAMINE GROUP-
dc.subjectIMMUNOASSAY-
dc.subjectDIAGNOSIS-
dc.subjectSPECTROSCOPY-
dc.subjectREGRESSION-
dc.subjectSCATTERING-
dc.titleFluorescence-based immunosensor using three-dimensional CNT network structure for sensitive and reproducible detection of oral squamous cell carcinoma biomarker-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Eui Seok-
dc.contributor.affiliatedAuthorYoon, Soo-Young-
dc.identifier.doi10.1016/j.aca.2018.04.025-
dc.identifier.scopusid2-s2.0-85046133946-
dc.identifier.wosid000434012800012-
dc.identifier.bibliographicCitationANALYTICA CHIMICA ACTA, v.1027, pp.101 - 108-
dc.relation.isPartOfANALYTICA CHIMICA ACTA-
dc.citation.titleANALYTICA CHIMICA ACTA-
dc.citation.volume1027-
dc.citation.startPage101-
dc.citation.endPage108-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusTUMOR-MARKERS-
dc.subject.keywordPlusCANCER BIOMARKERS-
dc.subject.keywordPlusSURFACE-DENSITY-
dc.subject.keywordPlusTHIN-LAYERS-
dc.subject.keywordPlusAMINE GROUP-
dc.subject.keywordPlusIMMUNOASSAY-
dc.subject.keywordPlusDIAGNOSIS-
dc.subject.keywordPlusSPECTROSCOPY-
dc.subject.keywordPlusREGRESSION-
dc.subject.keywordPlusSCATTERING-
dc.subject.keywordAuthorCyfra 21-1-
dc.subject.keywordAuthorFluorescence-based immunoassay-
dc.subject.keywordAuthorOral squamous cell carcinoma-
dc.subject.keywordAuthor3DN-CNTs-
dc.subject.keywordAuthorBiosensor-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Soo Young photo

Yoon, Soo Young
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE