Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jang, Yeon | - |
dc.contributor.author | Sim, Ji-Young | - |
dc.contributor.author | Park, Jong-Kyoung | - |
dc.contributor.author | Kim, Woong-Chul | - |
dc.contributor.author | Kim, Hae-Young | - |
dc.contributor.author | Kim, Ji-Hwan | - |
dc.date.accessioned | 2021-09-02T05:20:55Z | - |
dc.date.available | 2021-09-02T05:20:55Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2018-10 | - |
dc.identifier.issn | 2005-7806 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/72549 | - |
dc.description.abstract | PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (alpha=.05). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<120 mu m). | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN ACAD PROSTHODONTICS | - |
dc.subject | CONVENTIONAL IMPRESSIONS | - |
dc.subject | DIGITAL IMPRESSIONS | - |
dc.subject | IN-VITRO | - |
dc.subject | ACCURACY | - |
dc.subject | 3D | - |
dc.subject | REPRODUCIBILITY | - |
dc.subject | PROSTHODONTICS | - |
dc.subject | TECHNOLOGY | - |
dc.subject | ADAPTATION | - |
dc.subject | THICKNESS | - |
dc.title | Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Woong-Chul | - |
dc.contributor.affiliatedAuthor | Kim, Hae-Young | - |
dc.contributor.affiliatedAuthor | Kim, Ji-Hwan | - |
dc.identifier.doi | 10.4047/jap.2018.10.5.367 | - |
dc.identifier.scopusid | 2-s2.0-85056352916 | - |
dc.identifier.wosid | 000448342800006 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ADVANCED PROSTHODONTICS, v.10, no.5, pp.367 - 373 | - |
dc.relation.isPartOf | JOURNAL OF ADVANCED PROSTHODONTICS | - |
dc.citation.title | JOURNAL OF ADVANCED PROSTHODONTICS | - |
dc.citation.volume | 10 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 367 | - |
dc.citation.endPage | 373 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002395532 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordPlus | CONVENTIONAL IMPRESSIONS | - |
dc.subject.keywordPlus | DIGITAL IMPRESSIONS | - |
dc.subject.keywordPlus | IN-VITRO | - |
dc.subject.keywordPlus | ACCURACY | - |
dc.subject.keywordPlus | 3D | - |
dc.subject.keywordPlus | REPRODUCIBILITY | - |
dc.subject.keywordPlus | PROSTHODONTICS | - |
dc.subject.keywordPlus | TECHNOLOGY | - |
dc.subject.keywordPlus | ADAPTATION | - |
dc.subject.keywordPlus | THICKNESS | - |
dc.subject.keywordAuthor | Marginal and internal fit | - |
dc.subject.keywordAuthor | Intra oral scanner | - |
dc.subject.keywordAuthor | Digital light processing | - |
dc.subject.keywordAuthor | 3D printing model | - |
dc.subject.keywordAuthor | PolyJet | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.