A comparison of different thicknesses of mouthguards according to the groove shape of sheets
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Son, Ho-Jung | - |
dc.contributor.author | Sim, Ji-Young | - |
dc.contributor.author | Kim, Ji-Hwan | - |
dc.contributor.author | Kim, Woong-Chul | - |
dc.date.accessioned | 2021-09-02T05:35:35Z | - |
dc.date.available | 2021-09-02T05:35:35Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2018-10 | - |
dc.identifier.issn | 1600-4469 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/72667 | - |
dc.description.abstract | Background/aims: Previous studies have compared the thickness of the device with and without grooves. The result was a difference in thickness of the device along the groove. The aim of this study was to assess the differences in thickness of mouthguards that result from different groove shapes of ethylene vinyl acetate sheets used to make these appliances. Materials and Method: Mouthguards were made using a 3-dimensional printer, and produced by softening 4 mm transparent circular sheets. Four different shapes of sheets were evaluated: normal sheets, sheets with anterior V-shaped grooves, sheets with anterior A-shaped grooves, and sheets with posterior A-shaped grooves. The groove was 3 mm deep and 5 mm wide. The thickness of the appliance was assessed with respect to the anterior incisal edge, labial surface, palatal surface, posterior cusp, buccal surface, and palatal surface. The Kruskal-Wallis test was used to analyze differences in thickness among the different groove shapes. Results: No significant difference was detected between the thickness of mouthguards made using sheets with grooves and that of mouthguards made using sheets without grooves (P>.05). Conclusion: The presence of grooves on the sheets did not influence mouthguard thickness. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | ACETATE COPOLYMER SHEETS | - |
dc.subject | HEATING CONDITIONS | - |
dc.subject | FIT | - |
dc.title | A comparison of different thicknesses of mouthguards according to the groove shape of sheets | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Ji-Hwan | - |
dc.contributor.affiliatedAuthor | Kim, Woong-Chul | - |
dc.identifier.doi | 10.1111/edt.12410 | - |
dc.identifier.scopusid | 2-s2.0-85053618836 | - |
dc.identifier.wosid | 000445180500008 | - |
dc.identifier.bibliographicCitation | DENTAL TRAUMATOLOGY, v.34, no.5, pp.360 - 364 | - |
dc.relation.isPartOf | DENTAL TRAUMATOLOGY | - |
dc.citation.title | DENTAL TRAUMATOLOGY | - |
dc.citation.volume | 34 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 360 | - |
dc.citation.endPage | 364 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordPlus | ACETATE COPOLYMER SHEETS | - |
dc.subject.keywordPlus | HEATING CONDITIONS | - |
dc.subject.keywordPlus | FIT | - |
dc.subject.keywordAuthor | 3D printer | - |
dc.subject.keywordAuthor | ethylene vinyl acetate sheet | - |
dc.subject.keywordAuthor | mouthguard | - |
dc.subject.keywordAuthor | thickness | - |
dc.subject.keywordAuthor | vacuum pressure formation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.