Vibration control of a structure by a tuned liquid column damper with embossments
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, ByungJin | - |
dc.contributor.author | Lee, YongJae | - |
dc.contributor.author | Park, MinJae | - |
dc.contributor.author | Ju, Young K. | - |
dc.date.accessioned | 2021-09-02T07:53:21Z | - |
dc.date.available | 2021-09-02T07:53:21Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2018-08-01 | - |
dc.identifier.issn | 0141-0296 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/73804 | - |
dc.description.abstract | Several studies have examined damping mechanisms to improve damping effects in a tuned liquid column damper (TLCD). The additional damping mechanisms include orifices, valves, and the use of highly viscous liquids. In the present study, in contrast to previous studies, a damping mechanism using embossments on the wall of the TLCD was proposed, and TLCD with embossment (termed as ETLCD) was proposed as a new type of passive damper. The study focuses on an experimental evaluation of the dynamic characteristics of ETLCD and vibration control performance for tall buildings with ETLCD by using a shaking table. Thus, a characteristic experiment was performed with the presence of embossments, total length of the liquid column, and an excitation amplitude ratio as variables. Additionally, a scaled model test of the SDOF building composed of a free vibration test and sine sweep forced vibration test was conducted to verify the vibration control performance of the structure with ETLCD. Consequently, the equivalent damping ratios of conventional TLCD and ETLCD were experimentally compared, and the theoretical natural frequency of TLCD was re-evaluated in the characteristic experiment. Furthermore, the results of the scaled model test indicated that the vibration control performance of the ETLCD was superior to that of the conventional TLCD in terms of response reduction, efficiency, and stability. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCI LTD | - |
dc.subject | SLOSHING DAMPER | - |
dc.subject | DESIGN | - |
dc.subject | OPTIMIZATION | - |
dc.subject | MASS | - |
dc.title | Vibration control of a structure by a tuned liquid column damper with embossments | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Ju, Young K. | - |
dc.identifier.doi | 10.1016/j.engstruct.2018.04.074 | - |
dc.identifier.scopusid | 2-s2.0-85046370751 | - |
dc.identifier.wosid | 000435428400023 | - |
dc.identifier.bibliographicCitation | ENGINEERING STRUCTURES, v.168, pp.290 - 299 | - |
dc.relation.isPartOf | ENGINEERING STRUCTURES | - |
dc.citation.title | ENGINEERING STRUCTURES | - |
dc.citation.volume | 168 | - |
dc.citation.startPage | 290 | - |
dc.citation.endPage | 299 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.subject.keywordPlus | SLOSHING DAMPER | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordPlus | OPTIMIZATION | - |
dc.subject.keywordPlus | MASS | - |
dc.subject.keywordAuthor | Tuned liquid column damper | - |
dc.subject.keywordAuthor | Embossment | - |
dc.subject.keywordAuthor | Damping ratio | - |
dc.subject.keywordAuthor | Vibration control | - |
dc.subject.keywordAuthor | Free vibration test | - |
dc.subject.keywordAuthor | Sine sweep | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.