Enhanced resolution of a surface plasmon resonance sensor detecting C-reactive protein via a bimetallic waveguide-coupled mode approach
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Hwa-Seub | - |
dc.contributor.author | Seong, Tae-Yeon | - |
dc.contributor.author | Kim, Won Mok | - |
dc.contributor.author | Kim, Inho | - |
dc.contributor.author | Hwang, Gyu-Weon | - |
dc.contributor.author | Lee, Wook Seong | - |
dc.contributor.author | Lee, Kyeong-Seok | - |
dc.date.accessioned | 2021-09-02T07:54:27Z | - |
dc.date.available | 2021-09-02T07:54:27Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2018-08-01 | - |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/73814 | - |
dc.description.abstract | Extensive efforts have been devoted to improving the resolution of surface plasmon resonance (SPR) sensors in the detection of trace levels of biomolecules considered essential for the early diagnosis of disease. As part of these efforts, we previously developed a bimetallic waveguide-coupled surface plasmon resonance (Bi-WCSPR) sensor configuration designed to dramatically reduce the linewidth of the SPR curve while preserving a moderate local field decay length, thereby addressing the resolution issue. In this study, we systematically quantified the enhanced resolution in Bi-WCSPR sensors used to detect C-reactive protein (CRP), a widely accepted biomarker of inflammation in cardiovascular disease. Individual SPR sensorgrams were measured at several CRP concentrations in both the intensity and angular interrogation modes, confirming that the Bi-WCSPR configuration with a high Ag-to-Au ratio provided a figure-of-merit (FOM) that was 2.53 times higher than that of conventional Au sensors and a limit-of-detection (LOD) that was an order of magnitude lower than the cut-off level for CRP. It was found that when using the Bi-WCSPR configurations, the resolution enhancement in the intensity interrogation mode becomes more evident as the CRP concentrations is lowered to the cut-off level. (C) 2018 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE SA | - |
dc.subject | FIELD-EFFECT-TRANSISTOR | - |
dc.subject | UNSTABLE ANGINA | - |
dc.subject | SENSITIVITY | - |
dc.subject | BIOSENSORS | - |
dc.subject | RANGE | - |
dc.subject | IMMUNOSENSOR | - |
dc.subject | LAYERS | - |
dc.subject | FILM | - |
dc.subject | VARIANTS | - |
dc.subject | EVENTS | - |
dc.title | Enhanced resolution of a surface plasmon resonance sensor detecting C-reactive protein via a bimetallic waveguide-coupled mode approach | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Seong, Tae-Yeon | - |
dc.identifier.doi | 10.1016/j.snb.2018.03.136 | - |
dc.identifier.scopusid | 2-s2.0-85053783438 | - |
dc.identifier.wosid | 000430274200035 | - |
dc.identifier.bibliographicCitation | SENSORS AND ACTUATORS B-CHEMICAL, v.266, pp.311 - 317 | - |
dc.relation.isPartOf | SENSORS AND ACTUATORS B-CHEMICAL | - |
dc.citation.title | SENSORS AND ACTUATORS B-CHEMICAL | - |
dc.citation.volume | 266 | - |
dc.citation.startPage | 311 | - |
dc.citation.endPage | 317 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordPlus | FIELD-EFFECT-TRANSISTOR | - |
dc.subject.keywordPlus | UNSTABLE ANGINA | - |
dc.subject.keywordPlus | SENSITIVITY | - |
dc.subject.keywordPlus | BIOSENSORS | - |
dc.subject.keywordPlus | RANGE | - |
dc.subject.keywordPlus | IMMUNOSENSOR | - |
dc.subject.keywordPlus | LAYERS | - |
dc.subject.keywordPlus | FILM | - |
dc.subject.keywordPlus | VARIANTS | - |
dc.subject.keywordPlus | EVENTS | - |
dc.subject.keywordAuthor | Surface plasmon resonance sensor | - |
dc.subject.keywordAuthor | Bimetallic waveguide-coupled surface | - |
dc.subject.keywordAuthor | plasmon resonance | - |
dc.subject.keywordAuthor | C-reactive protein | - |
dc.subject.keywordAuthor | Resolution enhancement | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.