Safety investigation of hydrogen charging platform package with CFD simulation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Han, Ukmin | - |
dc.contributor.author | Oh, Jinwoo | - |
dc.contributor.author | Lee, Hoseong | - |
dc.date.accessioned | 2021-09-02T08:54:42Z | - |
dc.date.available | 2021-09-02T08:54:42Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2018-07-19 | - |
dc.identifier.issn | 0360-3199 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/74320 | - |
dc.description.abstract | Hydrogen has been expected as one of the most promising green energy sources, especially in transportation section. Despite its great potential as a new source of energy, it is reluctant to build hydrogen charging stations for the fear of accidents such as hydrogen leakage, fire, and following explosion. To reduce those problems and promote the acceptance of hydrogen charging station, this study focuses on the hydrogen charging platform package (HCPP) which is a new type of the mobile hydrogen station. Hydrogen leakage cases are investigated using CFD (computational fluid dynamics) simulation. The simulation is performed with the whole configuration of the HCPP including main components, storage, compressor, and dispenser. Based on the risk assessment, hydrogen leak scenarios with high possibilities of accidents are simulated. The simulation results show the leak length of hydrogen gas, its dispersion, and the various ranges of volume ratios of leaked hydrogen gas. Based on the simulation results, it is clearly confirmed that the leaked hydrogen gas with high concentration stays inside the HCPP. Therefore, the effects of ventilation to reduce the possibility of the explosion are continuously considered to investigate the safety of the HCPP in the case of the leakage accident. (C) 2018 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | PERGAMON-ELSEVIER SCIENCE LTD | - |
dc.subject | SCALE UNINTENDED RELEASES | - |
dc.subject | FUELING STATIONS | - |
dc.subject | NUMERICAL-SIMULATION | - |
dc.subject | PASSIVE VENTILATION | - |
dc.subject | RISK-ASSESSMENT | - |
dc.subject | GAS RELEASES | - |
dc.subject | DISPERSION | - |
dc.subject | ACCIDENTS | - |
dc.subject | ENCLOSURE | - |
dc.subject | EXPLOSION | - |
dc.title | Safety investigation of hydrogen charging platform package with CFD simulation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Hoseong | - |
dc.identifier.doi | 10.1016/j.ijhydene.2018.05.116 | - |
dc.identifier.scopusid | 2-s2.0-85048476106 | - |
dc.identifier.wosid | 000439402900068 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, v.43, no.29, pp.13687 - 13699 | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF HYDROGEN ENERGY | - |
dc.citation.title | INTERNATIONAL JOURNAL OF HYDROGEN ENERGY | - |
dc.citation.volume | 43 | - |
dc.citation.number | 29 | - |
dc.citation.startPage | 13687 | - |
dc.citation.endPage | 13699 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalResearchArea | Energy & Fuels | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Physical | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
dc.subject.keywordPlus | SCALE UNINTENDED RELEASES | - |
dc.subject.keywordPlus | FUELING STATIONS | - |
dc.subject.keywordPlus | NUMERICAL-SIMULATION | - |
dc.subject.keywordPlus | PASSIVE VENTILATION | - |
dc.subject.keywordPlus | RISK-ASSESSMENT | - |
dc.subject.keywordPlus | GAS RELEASES | - |
dc.subject.keywordPlus | DISPERSION | - |
dc.subject.keywordPlus | ACCIDENTS | - |
dc.subject.keywordPlus | ENCLOSURE | - |
dc.subject.keywordPlus | EXPLOSION | - |
dc.subject.keywordAuthor | Mobile hydrogen station | - |
dc.subject.keywordAuthor | Hydrogen charging platform package | - |
dc.subject.keywordAuthor | Risk assessment | - |
dc.subject.keywordAuthor | Hydrogen leakage | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.