Comparative evaluation of refractive outcomes after implantation of two types of intraocular lenses with different diopter intervals (0.25 diopter versus 0.50 diopter)
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Minjung | - |
dc.contributor.author | Eom, Youngsub | - |
dc.contributor.author | Song, Jong Suk | - |
dc.contributor.author | Kim, Hyo Myung | - |
dc.date.accessioned | 2021-09-02T08:56:54Z | - |
dc.date.available | 2021-09-02T08:56:54Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2018-07-18 | - |
dc.identifier.issn | 1471-2415 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/74327 | - |
dc.description.abstract | Background: Intraocular lenses (IOLs) with different diopter (D) intervals may have different tolerance, and may provide different accuracy of refractive outcome after cataract surgery. The aim of the study is to compare the accuracy of refractive outcome after implantation of IOLs with different D intervals after cataract surgery. Methods: A total of 80 eyes from 40 patients who underwent phacoemulsification with implantation of a 0.50 D interval Akreos AO IOL in one eye and a 0.25 D interval Softec HD (TM) IOL in the other eye were enrolled. The percentages of eyes with refractive prediction error within +/- 0.50 D at one month after surgery were compared. To evaluate the effect of the dioptric errors of the IOL itself on refractive prediction error, the percentage of eyes with refractive prediction error within +/- 0.25 D of the IOL with a standard deviation (SD) of +/- 0.40 D was compared with that of the IOL with a SD of +/- 0.11 D through Monte Carlo simulations. Results: In this clinical study, the percentage of eyes with refractive prediction error within +/- 0.50 D by the Haigis formula in the Softec HD (TM) group (85.0%) was significantly greater than that in the Akreos AO group (57.5%; P = 0. 027). In Monte Carlo simulations, all percentages of eyes with refractive prediction error within +/- 0.25 D by the Haigis and SRK/T formulas in the Softec HD (TM) group were significantly greater than those in the Akreos AO group. Conclusions: The IOL with a 0.25 D interval was more accurate than the IOL with a 0.50 D interval in predicting refractive outcome after cataract surgery. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | BMC | - |
dc.subject | POWER CALCULATION | - |
dc.subject | HAIGIS FORMULAS | - |
dc.subject | ACCURACY | - |
dc.subject | SRK/T | - |
dc.subject | ERROR | - |
dc.subject | EYES | - |
dc.title | Comparative evaluation of refractive outcomes after implantation of two types of intraocular lenses with different diopter intervals (0.25 diopter versus 0.50 diopter) | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Eom, Youngsub | - |
dc.contributor.affiliatedAuthor | Song, Jong Suk | - |
dc.contributor.affiliatedAuthor | Kim, Hyo Myung | - |
dc.identifier.doi | 10.1186/s12886-018-0840-0 | - |
dc.identifier.scopusid | 2-s2.0-85050346797 | - |
dc.identifier.wosid | 000439096600001 | - |
dc.identifier.bibliographicCitation | BMC OPHTHALMOLOGY, v.18 | - |
dc.relation.isPartOf | BMC OPHTHALMOLOGY | - |
dc.citation.title | BMC OPHTHALMOLOGY | - |
dc.citation.volume | 18 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Ophthalmology | - |
dc.relation.journalWebOfScienceCategory | Ophthalmology | - |
dc.subject.keywordPlus | POWER CALCULATION | - |
dc.subject.keywordPlus | HAIGIS FORMULAS | - |
dc.subject.keywordPlus | ACCURACY | - |
dc.subject.keywordPlus | SRK/T | - |
dc.subject.keywordPlus | ERROR | - |
dc.subject.keywordPlus | EYES | - |
dc.subject.keywordAuthor | Intraocular lens power calculation | - |
dc.subject.keywordAuthor | Refractive outcomes | - |
dc.subject.keywordAuthor | Diopter intervals | - |
dc.subject.keywordAuthor | Bilateral cataract extraction | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.