Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Study on the Dose Uncertainties in the Lung during Passive Proton Irradiation with a Proton Beam Range Compensator

Full metadata record
DC Field Value Language
dc.contributor.authorYoo, Seung Hoon-
dc.contributor.authorSon, Jae Man-
dc.contributor.authorYoon, Myonggeun-
dc.contributor.authorPark, Sung Yong-
dc.contributor.authorShin, Dongho-
dc.contributor.authorMin, Byung Jun-
dc.date.accessioned2021-09-02T10:42:20Z-
dc.date.available2021-09-02T10:42:20Z-
dc.date.created2021-06-19-
dc.date.issued2018-06-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/75079-
dc.description.abstractA moving phantom is manufactured for mimicking lung model to study the dose uncertainty from CT number-stopping power conversion and dose calculation in the soft tissue, light lung tissue and bone regions during passive proton irradiation with compensator smearing value. The phantom is scanned with a CT system, and a proton beam irradiation plan is carried out with the use of a treatment planning system (Eclipse). In the case of the moving phantom, a RPM system is used for respiratory gating. The uncertainties in the dose distribution between the measured data and the planned data are investigated by a gamma analysis with 3%-3 mm acceptance criteria. To investigate smearing effect, three smearing values (0.3 cm, 0.7 cm, 1.2 cm) are used to for fixed and moving phantom system. For both fixed and moving phantom, uncertainties in the light lung tissue are severe than those in soft tissue region in which the dose uncertainties are within clinically tolerable ranges. As the smearing value increases, the uncertainty in the proton dose distribution decreases.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectSTEREOTACTIC BODY RADIOTHERAPY-
dc.subjectMODULATED RADIATION-THERAPY-
dc.subjectMONTE-CARLO SIMULATIONS-
dc.subjectX-RAY THERAPY-
dc.subjectSTAGE-I-
dc.subjectCANCER-
dc.subjectDISTRIBUTIONS-
dc.subjectCARCINOMA-
dc.subjectSURVIVAL-
dc.titleStudy on the Dose Uncertainties in the Lung during Passive Proton Irradiation with a Proton Beam Range Compensator-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoon, Myonggeun-
dc.identifier.doi10.3938/jkps.72.1369-
dc.identifier.scopusid2-s2.0-85048259849-
dc.identifier.wosid000434917800016-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.72, no.11, pp.1369 - 1378-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume72-
dc.citation.number11-
dc.citation.startPage1369-
dc.citation.endPage1378-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002353031-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusSTEREOTACTIC BODY RADIOTHERAPY-
dc.subject.keywordPlusMODULATED RADIATION-THERAPY-
dc.subject.keywordPlusMONTE-CARLO SIMULATIONS-
dc.subject.keywordPlusX-RAY THERAPY-
dc.subject.keywordPlusSTAGE-I-
dc.subject.keywordPlusCANCER-
dc.subject.keywordPlusDISTRIBUTIONS-
dc.subject.keywordPlusCARCINOMA-
dc.subject.keywordPlusSURVIVAL-
dc.subject.keywordAuthorProton therapy-
dc.subject.keywordAuthorDose uncertainty-
dc.subject.keywordAuthorGating-
dc.subject.keywordAuthorLung phantom-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Myong geun photo

Yoon, Myong geun
보건과학대학 (바이오의공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE