Study on the Dose Uncertainties in the Lung during Passive Proton Irradiation with a Proton Beam Range Compensator
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yoo, Seung Hoon | - |
dc.contributor.author | Son, Jae Man | - |
dc.contributor.author | Yoon, Myonggeun | - |
dc.contributor.author | Park, Sung Yong | - |
dc.contributor.author | Shin, Dongho | - |
dc.contributor.author | Min, Byung Jun | - |
dc.date.accessioned | 2021-09-02T10:42:20Z | - |
dc.date.available | 2021-09-02T10:42:20Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2018-06 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/75079 | - |
dc.description.abstract | A moving phantom is manufactured for mimicking lung model to study the dose uncertainty from CT number-stopping power conversion and dose calculation in the soft tissue, light lung tissue and bone regions during passive proton irradiation with compensator smearing value. The phantom is scanned with a CT system, and a proton beam irradiation plan is carried out with the use of a treatment planning system (Eclipse). In the case of the moving phantom, a RPM system is used for respiratory gating. The uncertainties in the dose distribution between the measured data and the planned data are investigated by a gamma analysis with 3%-3 mm acceptance criteria. To investigate smearing effect, three smearing values (0.3 cm, 0.7 cm, 1.2 cm) are used to for fixed and moving phantom system. For both fixed and moving phantom, uncertainties in the light lung tissue are severe than those in soft tissue region in which the dose uncertainties are within clinically tolerable ranges. As the smearing value increases, the uncertainty in the proton dose distribution decreases. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.subject | STEREOTACTIC BODY RADIOTHERAPY | - |
dc.subject | MODULATED RADIATION-THERAPY | - |
dc.subject | MONTE-CARLO SIMULATIONS | - |
dc.subject | X-RAY THERAPY | - |
dc.subject | STAGE-I | - |
dc.subject | CANCER | - |
dc.subject | DISTRIBUTIONS | - |
dc.subject | CARCINOMA | - |
dc.subject | SURVIVAL | - |
dc.title | Study on the Dose Uncertainties in the Lung during Passive Proton Irradiation with a Proton Beam Range Compensator | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yoon, Myonggeun | - |
dc.identifier.doi | 10.3938/jkps.72.1369 | - |
dc.identifier.scopusid | 2-s2.0-85048259849 | - |
dc.identifier.wosid | 000434917800016 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.72, no.11, pp.1369 - 1378 | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.title | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.volume | 72 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 1369 | - |
dc.citation.endPage | 1378 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002353031 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
dc.subject.keywordPlus | STEREOTACTIC BODY RADIOTHERAPY | - |
dc.subject.keywordPlus | MODULATED RADIATION-THERAPY | - |
dc.subject.keywordPlus | MONTE-CARLO SIMULATIONS | - |
dc.subject.keywordPlus | X-RAY THERAPY | - |
dc.subject.keywordPlus | STAGE-I | - |
dc.subject.keywordPlus | CANCER | - |
dc.subject.keywordPlus | DISTRIBUTIONS | - |
dc.subject.keywordPlus | CARCINOMA | - |
dc.subject.keywordPlus | SURVIVAL | - |
dc.subject.keywordAuthor | Proton therapy | - |
dc.subject.keywordAuthor | Dose uncertainty | - |
dc.subject.keywordAuthor | Gating | - |
dc.subject.keywordAuthor | Lung phantom | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.