Chronological Echocardiographic Changes in Healthy Term Neonates within Postnatal 72 Hours Using Doppler Studies
- Authors
- Ha, Kee Soo; Choi, Byung Min; Lee, Eun Hee; Shin, Jeonghee; Cho, Hyun Joo; Jang, Gi Young; Son, Chang Sung
- Issue Date
- 28-5월-2018
- Publisher
- KOREAN ACAD MEDICAL SCIENCES
- Keywords
- Doppler; Echocardiography; Neonate; Term Birth
- Citation
- JOURNAL OF KOREAN MEDICAL SCIENCE, v.33, no.22
- Indexed
- SCIE
SCOPUS
KCI
- Journal Title
- JOURNAL OF KOREAN MEDICAL SCIENCE
- Volume
- 33
- Number
- 22
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/75486
- DOI
- 10.3346/jkms.2018.33.e155
- ISSN
- 1011-8934
- Abstract
- Background: This study evaluated echocardiographic changes in full-term healthy neonates during early transitional period from postnatal 0-72 hours at 12-hour intervals by echocardiography. Methods: This was a prospective, observational, and longitudinal single-center cohort study. Morphometric, functional, systolic, diastolic, and tissue Doppler imaging (TDI) parameters (patent ductus arteriosus [PDA], aorta, superior vena cava [SVC], stroke volume [SV], cardiac output [CO], cardiac index [Cl], early diastolic flow velocity [E], late diastolic flow velocity [A], early filling in TDI [E'], peak systolic annular velocity in TDI [S'], late velocity peak in TDI [A'], and myocardial performance index [MPI]) were evaluated in left ventricle (LV) and right ventricle (RV) with 56 newborns. Results: Sizes and peak velocities of PDA before postnatal 24 hours were significantly changed than those after postnatal 24 hours. Aortic velocity time integral (VTI), systolic blood pressure (BI), LV SV/kg, LV CO/kg, LV Cl, and SVC flow/LV CO before 24 hours showed significantly changes than those after 24 hours. Also, LV and RV MPI before 24 hours were significantly higher than those after 24 hours. LV E/E' was significantly higher than RV E/E'. Conclusion: Postnatal 24 hours is critical time for hemodynamic closure of PDA because aortic VTI, systolic BP, LV SV, LV CO, LV Cl, and SVC flow/LV CO showed simultaneously significant changes after 24 hours at the same time as 24 hours of physiological closure of PDA. Chronological and dramatic changes of systolic, diastolic, and TDI parameters during early postnatal period can be used to compile normal baseline data ofhealthy full-term neonates.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medicine > Department of Medical Science > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.